User name adev
Log entry time 04:08:42 on January 11, 2001
Entry number 54272
keyword=Start_Run_1176_Tar=carbon,Type=Optics,Lmom=1.170,Rmom=1.170,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1176 at Thu Jan 11 04:08:18 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 879.62
Right Arm Q1 momentum : 1.16981
Right Arm Q1 gauss meter : -0.021963
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 503.491
Right Arm Q2 momentum : 1.16991
Right Arm Q2 gauss meter : 0.2648
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 399.96
Right Arm D1 momentum : 1.16997
Right Arm D1 NMR : 0.434163
Right Arm Q3 power supply current : 465.783
Right Arm Q3 momentum : 1.17058
Right Arm Q3 gauss meter : 0.2085
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 879.97
Left Arm Q1 momentum : 1.16966
Left Arm Q1 gauss meter : -0.07437
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 503.945
Left Arm Q2 momentum : 1.17033
Left Arm Q2 gauss meter : 0.2663
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 391.978
Left Arm D1 momentum : 1.17001
Left Arm D1 NMR : 0.433128
Left Arm Q3 power supply current : 465.781
Left Arm Q3 momentum : 1.16996
Left Arm Q3 gauss meter : -0.2321
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.12922
Current on Unser monitor : 16.2313
Current on Upstream bcm : 5.14321
Current on Downstream bcm : 5.11523
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 63.1283
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.17094
haBDSPOS : 708450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.76
haSC200_6_Sensor_2_R : 16.22
haSC200_6_Sensor_3_R : 2.74
haSC200_6_Sensor_4_R : 39.51
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 96.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.54
haITC502_5_Sensor_2_R : 88.58
haITC502_5_Sensor_3_R : 273.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.2
Right Arm Arm Collimator : 0.364111
Left Arm Arm Collimator : 0.366064
HacR_HPM_LVDT:VALr : -802
HacR_VPM_LVDT:VALr : -1277
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.338396
HacR_alignPITCH : -0.013503
HacR_alignHPT : -1.84108
HacL_HPM_LVDT:VALr : -6923
HacL_VPM_LVDT:VALr : 1249
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL :
HacL_alignPITCH : -0.0923764
HacL_alignHPT : 3.82516
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5538
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5127
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 123
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88