User name adev
Log entry time 05:49:39 on January 11, 2001
Entry number 54289
keyword=End_of_Run_1183
End-of-run EPICS data for Run Number 1183 at Thu Jan 11 05:49:20 EST 2001
Right Arm D1 momentum : 1.147
Right Arm arm angle : 12.5537
Left Arm D1 momentum : 1.147
Left Arm arm angle : 12.5124
Tiefenbach Hall A energy : 1173.61
Right Arm arm mispointing (HPT) : -1.82355
Left Arm arm mispointing (HPT) : 3.86519
Right Arm Q1 power supply current : 862.33
Right Arm Q1 momentum : 1.14681
Right Arm Q1 gauss meter : -0.021541
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 493.616
Right Arm Q2 momentum : 1.14696
Right Arm Q2 gauss meter : 0.2594
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 392.707
Right Arm D1 momentum : 1.147
Right Arm D1 NMR : 0.425638
Right Arm Q3 power supply current : 456.21
Right Arm Q3 momentum : 1.14711
Right Arm Q3 gauss meter : 0.2044
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 862.715
Left Arm Q1 momentum : 1.14672
Left Arm Q1 gauss meter : -0.07292
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 493.942
Left Arm Q2 momentum : 1.1471
Left Arm Q2 gauss meter : 0.2611
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 384.063
Left Arm D1 momentum : 1.147
Left Arm D1 NMR : 0.424621
Left Arm Q3 power supply current : 456.678
Left Arm Q3 momentum : 1.14709
Left Arm Q3 gauss meter : -0.2276
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.52135
Current on Unser monitor : 17.0275
Current on Upstream bcm : 5.64158
Current on Downstream bcm : 5.40112
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 63.0469
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.61
Tiefenbach Hall C energy : 3395.12
Delta(E)/E width (MV_AI_DXWID) : 1.41818
IPM1C12.XPOS : 0.00170332
IPM1H04A.XPOS : -0.711457
IPM1H04A.YPOS : 0.439895
IPM1H04B.XPOS : -0.00925991
IPM1H04B.YPOS : -0.048293
Right Arm Arm Collimator : 0.364111
Left Arm Arm Collimator : 0.365918
HacR_HPM_LVDT:VALr : -820
HacR_VPM_LVDT:VALr : -1264
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.817383
HacR_alignROLL : -0.336685
HacR_alignPITCH : -0.0146661
HacR_alignHPT : -1.82191
HacL_HPM_LVDT:VALr : -6963
HacL_VPM_LVDT:VALr : 1254
HacL_HPE1313A:0_Ch58 : -0.191406
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.37408
HacL_alignPITCH : -0.0942013
HacL_alignHPT : 3.86646
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 21.64
haH2_P_Exhaust_R : 22.01
haH2_P_Fill_Bottle_R : 22.06
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.13
haD2_P_Exhaust_R : 19.69
haD2_P_Fill_Bottle_R : 38.85
haD2_DP_Fill_Exhaust_R : 0.0759
haSC200_6_Sensor_1_R : 242.6
haSC200_6_Sensor_2_R : 16.34
haSC200_6_Sensor_3_R : 3.14
haSC200_6_Sensor_4_R : 39.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 94.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.13
haITC502_5_Sensor_2_R : 88.08
haITC502_5_Sensor_3_R : 271.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.365869
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 124
Laser power Hall A : 57
Half-wave plate (off=out) : OFF