User name adev
Log entry time 07:01:44 on January 11, 2001
Entry number 54293
keyword=Start_Run_1185_Tar=carbon,Type=Optics,Lmom=1.123,Rmom=1.123,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1185 at Thu Jan 11 07:01:20 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 844.445
Right Arm Q1 momentum : 1.12303
Right Arm Q1 gauss meter : -0.021098
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 483.184
Right Arm Q2 momentum : 1.12272
Right Arm Q2 gauss meter : 0.2541
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 384.281
Right Arm D1 momentum : 1.12299
Right Arm D1 NMR : 0.416728
Right Arm Q3 power supply current : 446.836
Right Arm Q3 momentum : 1.12245
Right Arm Q3 gauss meter : 0.20013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 844.585
Left Arm Q1 momentum : 1.12262
Left Arm Q1 gauss meter : -0.0714
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 483.722
Left Arm Q2 momentum : 1.12337
Left Arm Q2 gauss meter : 0.2556
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 375.869
Left Arm D1 momentum : 1.123
Left Arm D1 NMR : 0.415746
Left Arm Q3 power supply current : 447.1
Left Arm Q3 momentum : 1.12303
Left Arm Q3 gauss meter : -0.2228
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.42409
Current on Unser monitor : 16.7269
Current on Upstream bcm : 5.53531
Current on Downstream bcm : 5.31288
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 39.9921
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.17094
haBDSPOS : 708450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 31.5
haSC200_6_Sensor_1_R : 241.86
haSC200_6_Sensor_2_R : 15.81
haSC200_6_Sensor_3_R : 2.69
haSC200_6_Sensor_4_R : 39.5
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.07
haITC502_5_Sensor_2_R : 88.02
haITC502_5_Sensor_3_R : 273.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366113
HacR_HPM_LVDT:VALr : -801
HacR_VPM_LVDT:VALr : -1293
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.817871
HacR_alignROLL : -0.337294
HacR_alignPITCH : -0.0145334
HacR_alignHPT : -1.83947
HacL_HPM_LVDT:VALr : -6928
HacL_VPM_LVDT:VALr : 1234
HacL_HPE1313A:0_Ch58 : -0.191895
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL : 0.374157
HacL_alignPITCH : -0.0933967
HacL_alignHPT : 3.82843
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5538
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.5127
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 123
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88