User name adev
Log entry time 07:23:59 on January 11, 2001
Entry number 54297
keyword=Start_Run_1187_Tar=9foil-12C,Type=Optics,Lmom=1.123,Rmom=1.123,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1187 at Thu Jan 11 07:23:30 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=75,ps2=10000,ps3=75,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 844.375
Right Arm Q1 momentum : 1.12294
Right Arm Q1 gauss meter : -0.021086
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 483.191
Right Arm Q2 momentum : 1.12274
Right Arm Q2 gauss meter : 0.2541
Right Arm Q2 power supply polarity :
Right Arm D1 power supply current : 384.302
Right Arm D1 momentum : 1.123
Right Arm D1 NMR : 0.416733
Right Arm Q3 power supply current : 446.756
Right Arm Q3 momentum : 1.12276
Right Arm Q3 gauss meter : 0.20013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 844.585
Left Arm Q1 momentum : 1.12262
Left Arm Q1 gauss meter : -0.07142
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 483.708
Left Arm Q2 momentum : 1.12334
Left Arm Q2 gauss meter : 0.2556
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 375.871
Left Arm D1 momentum : 1.123
Left Arm D1 NMR : 0.415746
Left Arm Q3 power supply current : 447.014
Left Arm Q3 momentum : 1.12282
Left Arm Q3 gauss meter : -0.2228
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.68873
Current on Unser monitor : 16.9403
Current on Upstream bcm : 5.71665
Current on Downstream bcm : 5.66081
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 49.154
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.192918
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.73
haSC200_6_Sensor_2_R : 15.72
haSC200_6_Sensor_3_R : 2.68
haSC200_6_Sensor_4_R : 39.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.08
haITC502_5_Sensor_2_R : 87.98
haITC502_5_Sensor_3_R : 271.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.07
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -785
HacR_VPM_LVDT:VALr : -1281
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.338831
HacR_alignPITCH : -0.0140182
HacR_alignHPT : -1.85874
HacL_HPM_LVDT:VALr : -6955
HacL_VPM_LVDT:VALr : 1250
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : 0.0336914
HacL_alignROLL : 0.37315
HacL_alignPITCH : -0.09245
HacL_alignHPT : 3.8602
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.554
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5124
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 122
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88