User name adev
Log entry time 08:18:11 on January 11, 2001
Entry number 54312
keyword=End_of_Run_1192
End-of-run EPICS data for Run Number 1192 at Thu Jan 11 08:17:50 EST 2001
Right Arm D1 momentum : 1.09
Right Arm arm angle : 12.5541
Left Arm D1 momentum : 1.09
Left Arm arm angle : 12.5124
Tiefenbach Hall A energy : 1173.61
Right Arm arm mispointing (HPT) : -1.87358
Left Arm arm mispointing (HPT) : 3.85976
Right Arm Q1 power supply current : 819.665
Right Arm Q1 momentum : 1.09007
Right Arm Q1 gauss meter : -0.020483
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 468.974
Right Arm Q2 momentum : 1.08971
Right Arm Q2 gauss meter : 0.2465
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 372.184
Right Arm D1 momentum : 1.08999
Right Arm D1 NMR : 0.404483
Right Arm Q3 power supply current : 433.71
Right Arm Q3 momentum : 1.08997
Right Arm Q3 gauss meter : 0.19434
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 819.875
Left Arm Q1 momentum : 1.08978
Left Arm Q1 gauss meter : -0.06934
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 469.163
Left Arm Q2 momentum : 1.09025
Left Arm Q2 gauss meter : 0.2481
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 364.659
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.403528
Left Arm Q3 power supply current : 433.982
Left Arm Q3 momentum : 1.09008
Left Arm Q3 gauss meter : -0.2162
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.6079
Current on Unser monitor : 16.9118
Current on Upstream bcm : 5.55536
Current on Downstream bcm : 5.66044
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 48.6065
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.6
Tiefenbach Hall C energy : 3395.34
Delta(E)/E width (MV_AI_DXWID) : 1.38151
IPM1C12.XPOS : -1.40689
IPM1H04A.XPOS : -0.862706
IPM1H04A.YPOS : -0.0603265
IPM1H04B.XPOS : -0.204729
IPM1H04B.YPOS : -0.572651
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : -771
HacR_VPM_LVDT:VALr : -1252
HacR_HPE1313A:0_Ch58 : -0.54248
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : -0.338831
HacR_alignPITCH : -0.0135694
HacR_alignHPT : -1.87441
HacL_HPM_LVDT:VALr : -6955
HacL_VPM_LVDT:VALr : 1268
HacL_HPE1313A:0_Ch58 : -0.191895
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL : 0.375086
HacL_alignPITCH : -0.0929601
HacL_alignHPT : 3.85927
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.7134
haL3_Fan_frequency_R : 31.7303
haH2_P_Fill_Target_R : 21.84
haH2_P_Exhaust_R : 22.25
haH2_P_Fill_Bottle_R : 22.28
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.15
haD2_P_Exhaust_R : 19.98
haD2_P_Fill_Bottle_R : 39.43
haD2_DP_Fill_Exhaust_R : 0.0765
haSC200_6_Sensor_1_R : 241.93
haSC200_6_Sensor_2_R : 15.82
haSC200_6_Sensor_3_R : 2.79
haSC200_6_Sensor_4_R : 39.56
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 92.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.09
haITC502_5_Sensor_2_R : 87.93
haITC502_5_Sensor_3_R : 271.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.06
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868604
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 125
Laser power Hall A : 57
Half-wave plate (off=out) : OFF