User name adev
Log entry time 10:34:23 on January 11, 2001
Entry number 54326
keyword=End_of_Run_1196
End-of-run EPICS data for Run Number 1196 at Thu Jan 11 10:34:00 EST 2001
Right Arm D1 momentum : 0.838001
Right Arm arm angle : 41.435
Left Arm D1 momentum : 0.83799
Left Arm arm angle : 41.41
Tiefenbach Hall A energy : 1173.62
Right Arm arm mispointing (HPT) : 2.52311
Left Arm arm mispointing (HPT) : 5.15808
Right Arm Q1 power supply current : 630.175
Right Arm Q1 momentum : 0.838071
Right Arm Q1 gauss meter : -0.015772
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current :
Right Arm Q2 momentum : 0.838088
Right Arm Q2 gauss meter : 0.18961
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.03
Right Arm D1 momentum : 0.837998
Right Arm D1 NMR : 0.310971
Right Arm Q3 power supply current : 333.485
Right Arm Q3 momentum : 0.838069
Right Arm Q3 gauss meter : 0.14945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.49
Left Arm Q1 momentum : 0.838048
Left Arm Q1 gauss meter : -0.05336
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 360.686
Left Arm Q2 momentum : 0.837635
Left Arm Q2 gauss meter : 0.19077
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 279.776
Left Arm D1 momentum : 0.83799
Left Arm D1 NMR : 0.31029
Left Arm Q3 power supply current : 333.596
Left Arm Q3 momentum : 0.837932
Left Arm Q3 gauss meter : -0.16624
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0405755
Current on Unser monitor : 10.6185
Current on Upstream bcm : 0.0466849
Current on Downstream bcm : 0.0344661
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.62
Tiefenbach Hall C energy : 3394.2
Delta(E)/E width (MV_AI_DXWID) : 1.42214
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4732
HacR_VPM_LVDT:VALr : 465
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.933594
HacR_alignROLL : -0.456528
HacR_alignPITCH : -0.0119067
HacR_alignHPT : 2.52417
HacL_HPM_LVDT:VALr : -8007
HacL_VPM_LVDT:VALr : -367
HacL_HPE1313A:0_Ch58 : -0.228516
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.245605
HacL_alignROLL : 0.115347
HacL_alignPITCH : -0.0403963
HacL_alignHPT : 5.15605
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 32.7219
haL3_Fan_frequency_R : 31.7303
haH2_P_Fill_Target_R : 23.09
haH2_P_Exhaust_R : 23.48
haH2_P_Fill_Bottle_R : 23.58
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.12
haD2_P_Exhaust_R : 20.87
haD2_P_Fill_Bottle_R : 41.19
haD2_DP_Fill_Exhaust_R : 0.0759
haSC200_6_Sensor_1_R : 242.48
haSC200_6_Sensor_2_R : 15.97
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 39.8
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 91.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.49
haITC502_5_Sensor_2_R : 88.15
haITC502_5_Sensor_3_R : 271
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 200
Laser power Hall A : 57
Half-wave plate (off=out) : OFF