User name adev
Log entry time 13:38:43 on January 11, 2001
Entry number 54335
keyword=Start_Run_1200_Tar=9foil-12C,Type=Optics,Lmom=0.838,Rmom=0.838,Ene=1.173,Angle_R=41.435,Angle_L=41.410
Beginning-of-run EPICS data for Run Number 1200 at Thu Jan 11 13:38:29 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=40,ps3=1,ps4=40,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.105
Right Arm Q1 momentum : 0.837978
Right Arm Q1 gauss meter : -0.015782
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.65
Right Arm Q2 momentum : 0.838006
Right Arm Q2 gauss meter : 0.18972
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.037
Right Arm D1 momentum : 0.838
Right Arm D1 NMR : 0.310972
Right Arm Q3 power supply current : 333.585
Right Arm Q3 momentum : 0.838434
Right Arm Q3 gauss meter : 0.14945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.49
Left Arm Q1 momentum : 0.838048
Left Arm Q1 gauss meter : -0.05336
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 360.587
Left Arm Q2 momentum : 0.837406
Left Arm Q2 gauss meter : 0.19079
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 279.78
Left Arm D1 momentum : 0.837991
Left Arm D1 NMR : 0.31029
Left Arm Q3 power supply current : 333.646
Left Arm Q3 momentum : 0.837965
Left Arm Q3 gauss meter : -0.16626
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0408227
Current on Unser monitor : 12.902
Current on Upstream bcm : 0.0474495
Current on Downstream bcm : 0.034196
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.04029
Radiator Encoder : 0.161172
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.1
haSC200_6_Sensor_2_R : 15.76
haSC200_6_Sensor_3_R : 2.92
haSC200_6_Sensor_4_R : 39.65
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 91.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 92.67
haITC502_5_Sensor_2_R : 89.75
haITC502_5_Sensor_3_R : 270.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.03
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4766
HacR_VPM_LVDT:VALr : 507
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.94873
HacR_alignROLL : -0.469892
HacR_alignPITCH : -0.01588
HacR_alignHPT : 2.56871
HacL_HPM_LVDT:VALr : -8016
HacL_VPM_LVDT:VALr : -274
HacL_HPE1313A:0_Ch58 : -0.222656
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.237793
HacL_alignROLL : 0.123526
HacL_alignPITCH : -0.0454182
HacL_alignHPT : 5.16107
Right Arm Angle Floor Angle : 41.5
Right Arm Angle Vernier : -42.5
Right Arm Scattering Angle : 41.4346
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 21.5
Left Arm Scattering Angle : 41.41
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 350
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88