User name adev
Log entry time 14:28:06 on January 11, 2001
Entry number 54338
keyword=Start_Run_1201_Tar=9foil-12C,Type=Optics,Lmom=0.838,Rmom=0.838,Ene=1.173,Angle_R=41.435,Angle_L=41.410
Beginning-of-run EPICS data for Run Number 1201 at Thu Jan 11 14:27:42 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=120,ps3=1,ps4=120,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.105
Right Arm Q1 momentum :
Right Arm Q1 gauss meter : -0.015779
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.639
Right Arm Q2 momentum : 0.837979
Right Arm Q2 gauss meter : 0.18974
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.031
Right Arm D1 momentum : 0.837999
Right Arm D1 NMR : 0.310971
Right Arm Q3 power supply current : 333.37
Right Arm Q3 momentum : 0.838358
Right Arm Q3 gauss meter : 0.14946
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.455
Left Arm Q1 momentum : 0.838002
Left Arm Q1 gauss meter : -0.05336
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 360.86
Left Arm Q2 momentum : 0.838041
Left Arm Q2 gauss meter : 0.1908
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 279.779
Left Arm D1 momentum : 0.83799
Left Arm D1 NMR : 0.31029
Left Arm Q3 power supply current : 333.622
Left Arm Q3 momentum : 0.837997
Left Arm Q3 gauss meter : -0.16626
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0407691
Current on Unser monitor : 11.1158
Current on Upstream bcm : 0.0472297
Current on Downstream bcm : 0.0343085
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 11.1705
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 4.96459
Radiator Encoder : 0.15873
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 16.04
haSC200_6_Sensor_3_R : 3.06
haSC200_6_Sensor_4_R : 39.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 91.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.58
haITC502_5_Sensor_2_R : 91.59
haITC502_5_Sensor_3_R : 270.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.03
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4779
HacR_VPM_LVDT:VALr : 508
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.949707
HacR_alignROLL : -0.469892
HacR_alignPITCH : -0.0167776
HacR_alignHPT : 2.58425
HacL_HPM_LVDT:VALr : -8014
HacL_VPM_LVDT:VALr : -272
HacL_HPE1313A:0_Ch58 : -0.222656
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.236328
HacL_alignROLL : 0.124182
HacL_alignPITCH : -0.0456355
HacL_alignHPT : 5.16299
Right Arm Angle Floor Angle : 41.5
Right Arm Angle Vernier : -42.5
Right Arm Scattering Angle : 41.4345
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 21.5
Left Arm Scattering Angle : 41.4099
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 450
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88