User name adev
Log entry time 21:59:29 on January 11, 2001
Entry number 54362
keyword=Start_Run_1211_Tar=LH2-15cm,Type=Other,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.66,Angle_L=56.66
Beginning-of-run EPICS data for Run Number 1211 at Thu Jan 11 21:59:14 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 530.88
Right Arm Q1 momentum : 0.706019
Right Arm Q1 gauss meter : 0.013417
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 303.883
Right Arm Q2 momentum : 0.706102
Right Arm Q2 gauss meter : -0.15903
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 243.173
Right Arm D1 momentum : 0.706001
Right Arm D1 NMR : 0.261988
Right Arm Q3 power supply current : 281.069
Right Arm Q3 momentum : 0.706364
Right Arm Q3 gauss meter : -0.1256
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 530.88
Left Arm Q1 momentum : 0.705646
Left Arm Q1 gauss meter : 0.04551
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 304.048
Left Arm Q2 momentum : 0.706452
Left Arm Q2 gauss meter : -0.15907
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 236.195
Left Arm D1 momentum : 0.705997
Left Arm D1 NMR : 0.261455
Left Arm Q3 power supply current : 281.004
Left Arm Q3 momentum : 0.70583
Left Arm Q3 gauss meter : 0.13959
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 9.8334
Current on Unser monitor : 21.5886
Current on Upstream bcm : 10.0669
Current on Downstream bcm : 9.5999
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 54.7979
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.06471
Radiator Encoder : 0.151404
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.66
haSC200_6_Sensor_2_R : 15.77
haSC200_6_Sensor_3_R : 2.63
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.92
haITC502_4_Sensor_1_R : 96.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 95.36
haITC502_5_Sensor_3_R : 267.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.89
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1903
HacR_VPM_LVDT:VALr : 694
HacR_HPE1313A:0_Ch58 : -0.51709
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.859375
HacR_alignROLL : -0.378871
HacR_alignPITCH : -0.0367748
HacR_alignHPT : -0.762259
HacL_HPM_LVDT:VALr : -959
HacL_VPM_LVDT:VALr : -404
HacL_HPE1313A:0_Ch58 : -0.30957
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.290527
HacL_alignROLL : 0.0744275
HacL_alignPITCH : 0.0323614
HacL_alignHPT : -2.70436
Right Arm Angle Floor Angle : -29
Right Arm Angle Vernier : -6.2
Right Arm Scattering Angle : 65.1664
Left Arm Angle Floor Angle : 56.66
Left Arm Angle Vernier : 56.66
Left Arm Scattering Angle : 56.8259
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 112
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88