User name adev
Log entry time 22:21:59 on January 11, 2001
Entry number 54364
keyword=Start_Run_1212_Tar=LH2-15cm,Type=Other,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.66,Angle_L=56.66
Beginning-of-run EPICS data for Run Number 1212 at Thu Jan 11 22:21:33 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 530.775
Right Arm Q1 momentum : 0.705879
Right Arm Q1 gauss meter : 0.013428
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 303.791
Right Arm Q2 momentum : 0.705887
Right Arm Q2 gauss meter : -0.15897
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 243.25
Right Arm D1 momentum : 0.706
Right Arm D1 NMR : 0.261988
Right Arm Q3 power supply current : 280.907
Right Arm Q3 momentum : 0.705959
Right Arm Q3 gauss meter : -0.1256
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 530.88
Left Arm Q1 momentum : 0.705646
Left Arm Q1 gauss meter : 0.04556
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 303.852
Left Arm Q2 momentum : 0.705647
Left Arm Q2 gauss meter : -0.159
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 236.19
Left Arm D1 momentum : 0.705998
Left Arm D1 NMR : 0.261455
Left Arm Q3 power supply current : 281.132
Left Arm Q3 momentum : 0.706152
Left Arm Q3 gauss meter : 0.13956
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 9.8187
Current on Unser monitor : 20.9181
Current on Upstream bcm : 9.97341
Current on Downstream bcm : 9.74316
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 57.8388
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.03053
Radiator Encoder : 1.46276
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.86
haSC200_6_Sensor_2_R : 15.87
haSC200_6_Sensor_3_R : 2.74
haSC200_6_Sensor_4_R : 39.6
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.77
haITC502_4_Sensor_1_R : 96.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 95.15
haITC502_5_Sensor_3_R : 267.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.89
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1903
HacR_VPM_LVDT:VALr : 714
HacR_HPE1313A:0_Ch58 : -0.516113
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.854492
HacR_alignROLL : -0.374378
HacR_alignPITCH : -0.0377394
HacR_alignHPT : -0.75212
HacL_HPM_LVDT:VALr : -1170
HacL_VPM_LVDT:VALr : -398
HacL_HPE1313A:0_Ch58 : -0.308594
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.293457
HacL_alignROLL : 0.0719178
HacL_alignPITCH : 0.0313473
HacL_alignHPT : -2.46613
Right Arm Angle Floor Angle : 56.5
Right Arm Angle Vernier : -6.2
Right Arm Scattering Angle : 56.6664
Left Arm Angle Floor Angle : 57
Left Arm Angle Vernier : -29
Left Arm Scattering Angle : 56.6706
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 111
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88