User name adev
Log entry time 22:49:55 on January 11, 2001
Entry number 54368
keyword=Start_Run_1214_Tar=LH2-15cm,Type=Other,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.66,Angle_L=56.66
Beginning-of-run EPICS data for Run Number 1214 at Thu Jan 11 22:49:32 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.705972
Right Arm Q1 gauss meter : 0.013418
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 303.784
Right Arm Q2 momentum : 0.70587
Right Arm Q2 gauss meter : -0.15901
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 243.267
Right Arm D1 momentum : 0.705999
Right Arm D1 NMR : 0.261988
Right Arm Q3 power supply current : 280.932
Right Arm Q3 momentum : 0.706021
Right Arm Q3 gauss meter : -0.12551
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 530.95
Left Arm Q1 momentum : 0.705739
Left Arm Q1 gauss meter : 0.04553
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 303.897
Left Arm Q2 momentum : 0.705635
Left Arm Q2 gauss meter : -0.15905
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 236.189
Left Arm D1 momentum :
Left Arm D1 NMR : 0.261457
Left Arm Q3 power supply current : 281.013
Left Arm Q3 momentum : 0.705851
Left Arm Q3 gauss meter : 0.13958
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.17258
Current on Unser monitor : 15.9797
Current on Upstream bcm : 5.16536
Current on Downstream bcm : 5.14867
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 51.5803
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.03053
Radiator Encoder : 4.75458
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 35
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.05
haSC200_6_Sensor_2_R : 16.04
haSC200_6_Sensor_3_R : 2.87
haSC200_6_Sensor_4_R : 39.68
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.87
haITC502_4_Sensor_1_R : 96.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 94.92
haITC502_5_Sensor_3_R : 267.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.89
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1907
HacR_VPM_LVDT:VALr : 0
HacR_HPE1313A:0_Ch58 : -0.514648
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.851562
HacR_alignROLL : -0.371971
HacR_alignPITCH : -0.0403653
HacR_alignHPT : -0.749015
HacL_HPM_LVDT:VALr : -1324
HacL_VPM_LVDT:VALr : -394
HacL_HPE1313A:0_Ch58 : -0.308105
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.29541
HacL_alignROLL : 0.0702212
HacL_alignPITCH : 0.03084
HacL_alignHPT : -2.29278
Right Arm Angle Floor Angle : 56.5
Right Arm Angle Vernier : -6.2
Right Arm Scattering Angle : 56.6663
Left Arm Angle Floor Angle : 57
Left Arm Angle Vernier : -29
Left Arm Scattering Angle : 56.6694
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 250
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88