User name adev
Log entry time 23:16:04 on January 11, 2001
Entry number 54371
keyword=Start_Run_1215_Tar=dum-15cm,Type=Other,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.66,Angle_L=56.66
Beginning-of-run EPICS data for Run Number 1215 at Thu Jan 11 23:15:43 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 530.845
Right Arm Q1 momentum : 0.705972
Right Arm Q1 gauss meter : 0.013418
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 304.021
Right Arm Q2 momentum : 0.706421
Right Arm Q2 gauss meter : -0.15909
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 243.268
Right Arm D1 momentum : 0.705999
Right Arm D1 NMR : 0.261988
Right Arm Q3 power supply current : 280.894
Right Arm Q3 momentum : 0.705925
Right Arm Q3 gauss meter : -0.12559
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 530.95
Left Arm Q1 momentum : 0.705739
Left Arm Q1 gauss meter : 0.04554
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 303.929
Left Arm Q2 momentum : 0.705826
Left Arm Q2 gauss meter : -0.15902
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 236.189
Left Arm D1 momentum : 0.706004
Left Arm D1 NMR : 0.261458
Left Arm Q3 power supply current : 281.097
Left Arm Q3 momentum : 0.706062
Left Arm Q3 gauss meter : 0.13956
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 19.4993
Current on Unser monitor : 30.938
Current on Upstream bcm : 19.6166
Current on Downstream bcm : 19.3819
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 66.0023
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.03785
Radiator Encoder : 4.75946
haBDSPOS : -44998
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 32.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 16.07
haSC200_6_Sensor_3_R : 2.94
haSC200_6_Sensor_4_R : 39.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.33
haITC502_4_Sensor_1_R : 96.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 94.84
haITC502_5_Sensor_3_R : 272.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1905
HacR_VPM_LVDT:VALr : 712
HacR_HPE1313A:0_Ch58 : -0.513672
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 :
HacR_alignROLL : -0.369942
HacR_alignPITCH : -0.0395347
HacR_alignHPT : -0.751291
HacL_HPM_LVDT:VALr : -1433
HacL_VPM_LVDT:VALr : -385
HacL_HPE1313A:0_Ch58 : -0.307129
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.297363
HacL_alignROLL : 0.0688961
HacL_alignPITCH : 0.0304034
HacL_alignHPT : -2.17016
Right Arm Angle Floor Angle : 56.5
Right Arm Angle Vernier : -6.2
Right Arm Scattering Angle : 56.6664
Left Arm Angle Floor Angle : 57
Left Arm Angle Vernier : -29
Left Arm Scattering Angle : 56.6686
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 160
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88