User name adev
Log entry time 23:23:24 on January 11, 2001
Entry number 54374
keyword=Start_Run_1216_Tar=dum-15cm,Type=Other,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.66,Angle_L=56.66
Beginning-of-run EPICS data for Run Number 1216 at Thu Jan 11 23:23:02 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 530.845
Right Arm Q1 momentum : 0.705972
Right Arm Q1 gauss meter : 0.013422
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 303.919
Right Arm Q2 momentum : 0.706184
Right Arm Q2 gauss meter : -0.15902
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 243.267
Right Arm D1 momentum : 0.706
Right Arm D1 NMR : 0.261988
Right Arm Q3 power supply current : 280.737
Right Arm Q3 momentum : 0.705532
Right Arm Q3 gauss meter : -0.12554
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 530.985
Left Arm Q1 momentum : 0.705786
Left Arm Q1 gauss meter : 0.04553
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 303.875
Left Arm Q2 momentum : 0.705702
Left Arm Q2 gauss meter : -0.159
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 236.187
Left Arm D1 momentum :
Left Arm D1 NMR : 0.261458
Left Arm Q3 power supply current : 281.126
Left Arm Q3 momentum : 0.706135
Left Arm Q3 gauss meter : 0.13958
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.90215
Current on Unser monitor : 16.7767
Current on Upstream bcm : 4.98254
Current on Downstream bcm : 4.82177
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 51.9725
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 4.74725
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 32.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 16.09
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 39.73
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.18
haITC502_4_Sensor_1_R : 96.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 94.84
haITC502_5_Sensor_3_R : 271.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.09
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1907
HacR_VPM_LVDT:VALr : 710
HacR_HPE1313A:0_Ch58 : -0.513184
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.849609
HacR_alignROLL : -0.369392
HacR_alignPITCH : -0.0404993
HacR_alignHPT : -0.750485
HacL_HPM_LVDT:VALr : -1459
HacL_VPM_LVDT:VALr : -386
HacL_HPE1313A:0_Ch58 : -0.307129
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.296387
HacL_alignROLL : 0
HacL_alignPITCH : 0.0299668
HacL_alignHPT : -2.14464
Right Arm Angle Floor Angle : 56.5
Right Arm Angle Vernier : -6.2
Right Arm Scattering Angle : 56.6663
Left Arm Angle Floor Angle : 57
Left Arm Angle Vernier : -29
Left Arm Scattering Angle : 56.6684
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 215
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88