User name adev
Log entry time 04:16:31 on January 12, 2001
Entry number 54400
keyword=Start_Run_1228_Tar=dum-15cm,Type=Optics,Lmom=0.550,Rmom=0.600,Ene=1.173,Angle_R=13.936,Angle_L=13.704
Beginning-of-run EPICS data for Run Number 1228 at Fri Jan 12 04:16:16 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=200,ps3=1,ps4=200,ps5=1000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 451.045
Right Arm Q1 momentum : 0.599846
Right Arm Q1 gauss meter : -0.01126
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 258.358
Right Arm Q2 momentum : 0.600321
Right Arm Q2 gauss meter : 0.13603
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 206.798
Right Arm D1 momentum : 0.599998
Right Arm D1 NMR : 0.222652
Right Arm Q3 power supply current : 238.953
Right Arm Q3 momentum : 0.600523
Right Arm Q3 gauss meter : 0.10712
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 413.385
Left Arm Q1 momentum : 0.549472
Left Arm Q1 gauss meter : 0.03565
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 236.808
Left Arm Q2 momentum : 0.54995
Left Arm Q2 gauss meter : -0.12381
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 183.682
Left Arm D1 momentum : 0.550004
Left Arm D1 NMR : 0.203741
Left Arm Q3 power supply current : 219.009
Left Arm Q3 momentum : 0.550109
Left Arm Q3 gauss meter : 0.10882
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 3.14796
Current on Unser monitor : 14.001
Current on Upstream bcm : 3.11132
Current on Downstream bcm : 3.18459
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 45.5186
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.595849
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 15.92
haSC200_6_Sensor_3_R : 2.92
haSC200_6_Sensor_4_R : 39.7
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 93.55
haITC502_4_Sensor_1_R : 95.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 94.23
haITC502_5_Sensor_3_R : 271
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.01
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -484
HacR_VPM_LVDT:VALr : -854
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.774902
HacR_alignROLL : -0.294034
HacR_alignPITCH : -0.0202354
HacR_alignHPT : -2.27201
HacL_HPM_LVDT:VALr : -6845
HacL_VPM_LVDT:VALr : 1443
HacL_HPE1313A:0_Ch58 : -0.193848
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0195312
HacL_alignROLL : 0.359752
HacL_alignPITCH : -0.0916504
HacL_alignHPT : 3.74261
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -48
Right Arm Scattering Angle : 13.9357
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : -16
Left Arm Scattering Angle : 13.7034
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 180
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88