User name adev
Log entry time 04:46:43 on January 12, 2001
Entry number 54406
keyword=Start_Run_1229_Tar=LH2-15cm,Type=Other,Lmom=0.550,Rmom=0.600,Ene=1.173,Angle_R=13.936,Angle_L=13.704
Beginning-of-run EPICS data for Run Number 1229 at Fri Jan 12 04:46:20 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=100,ps3=600,ps4=200,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 451.15
Right Arm Q1 momentum : 0.599985
Right Arm Q1 gauss meter : -0.011257
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 258.184
Right Arm Q2 momentum : 0.599915
Right Arm Q2 gauss meter : 0.13594
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 206.703
Right Arm D1 momentum : 0.6
Right Arm D1 NMR : 0.222653
Right Arm Q3 power supply current : 238.753
Right Arm Q3 momentum : 0.600019
Right Arm Q3 gauss meter : 0.10706
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 413.455
Left Arm Q1 momentum : 0.549565
Left Arm Q1 gauss meter : 0.03564
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 236.824
Left Arm Q2 momentum : 0.549985
Left Arm Q2 gauss meter : -0.12384
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 183.681
Left Arm D1 momentum : 0.550002
Left Arm D1 NMR : 0.20374
Left Arm Q3 power supply current : 219.079
Left Arm Q3 momentum : 0.550286
Left Arm Q3 gauss meter : 0.10884
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.6789
Current on Unser monitor : 17.6321
Current on Upstream bcm : 4.74446
Current on Downstream bcm : 4.61335
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 47.5663
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.593407
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.25
haSC200_6_Sensor_2_R : 15.97
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 39.75
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 93.46
haITC502_4_Sensor_1_R : 95.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 94.1
haITC502_5_Sensor_3_R : 267.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.89
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -499
HacR_VPM_LVDT:VALr : -876
HacR_HPE1313A:0_Ch58 : -0.53418
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.773438
HacR_alignROLL : -0.292989
HacR_alignPITCH : -0.0207507
HacR_alignHPT : -2.25553
HacL_HPM_LVDT:VALr : -6818
HacL_VPM_LVDT:VALr : 1426
HacL_HPE1313A:0_Ch58 : -0.193359
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.019043
HacL_alignROLL : 0.358899
HacL_alignPITCH : -0.0926708
HacL_alignHPT : 3.71192
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -48
Right Arm Scattering Angle : 13.9356
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : -16
Left Arm Scattering Angle : 13.7036
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 184
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88