Log entry time 05:57:19 on January 12, 2001
Entry number 54417
keyword=Start_Run_1234_Tar=LH2-15cm,Type=Other,Lmom=0.550,Rmom=0.600,Ene=1.173,Angle_R=13.936,Angle_L=13.704
Beginning-of-run EPICS data for Run Number 1234 at Fri Jan 12 05:56:59 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3000,ps2=400,ps3=3000,ps4=800,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 451.115
Right Arm Q1 momentum : 0.599939
Right Arm Q1 gauss meter : -0.011265
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 258.491
Right Arm Q2 momentum : 0.600628
Right Arm Q2 gauss meter : 0.13602
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 206.616
Right Arm D1 momentum : 0.599997
Right Arm D1 NMR : 0.222652
Right Arm Q3 power supply current : 238.85
Right Arm Q3 momentum : 0.600262
Right Arm Q3 gauss meter : 0.10706
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 413.49
Left Arm Q1 momentum : 0.549611
Left Arm Q1 gauss meter : 0.03564
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current :
Left Arm Q2 momentum : 0.549834
Left Arm Q2 gauss meter : -0.12379
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 183.681
Left Arm D1 momentum : 0.550005
Left Arm D1 NMR : 0.203741
Left Arm Q3 power supply current : 218.974
Left Arm Q3 momentum : 0.550022
Left Arm Q3 gauss meter : 0.10881
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 19.4102
Current on Unser monitor : 31.2235
Current on Upstream bcm : 19.4942
Current on Downstream bcm : 19.3262
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 77.4398
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.590965
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.38
haSC200_6_Sensor_2_R : 16.06
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 39.8
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 92.69
haITC502_4_Sensor_1_R : 95.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.86
haITC502_5_Sensor_3_R : 267.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.89
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -497
HacR_VPM_LVDT:VALr : -884
HacR_HPE1313A:0_Ch58 : -0.533691
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.771484
HacR_alignROLL : -0.290347
HacR_alignPITCH : -0.0213991
HacR_alignHPT : -2.25844
HacL_HPM_LVDT:VALr : -6819
HacL_VPM_LVDT:VALr : 1414
HacL_HPE1313A:0_Ch58 : -0.191895
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0180664
HacL_alignROLL : 0.358977
HacL_alignPITCH : -0.0931075
HacL_alignHPT : 3.71393
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -48
Right Arm Scattering Angle : 13.9356
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : -16
Left Arm Scattering Angle : 13.7036
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 161
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88