User name adev
Log entry time 09:07:19 on January 12, 2001
Entry number 54425
keyword=Start_Run_1235_Tar=LH2-15cm,Type=Other,Lmom=0.557,Rmom=01.02,Ene=1.173,Angle_R=28.327,Angle_L=60.405
Beginning-of-run EPICS data for Run Number 1235 at Fri Jan 12 09:06:59 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3000,ps2=400,ps3=3000,ps4=800,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 766.955
Right Arm Q1 momentum : 1.01998
Right Arm Q1 gauss meter : -0.019137
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 438.926
Right Arm Q2 momentum : 1.01976
Right Arm Q2 gauss meter : 0.2307
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 349.964
Right Arm D1 momentum : 1.02
Right Arm D1 NMR : 0.378509
Right Arm Q3 power supply current : 405.718
Right Arm Q3 momentum : 1.01963
Right Arm Q3 gauss meter : 0.18182
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 418.915
Left Arm Q1 momentum : 0.556729
Left Arm Q1 gauss meter : 0.03611
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 239.943
Left Arm Q2 momentum : 0.55723
Left Arm Q2 gauss meter : -0.12542
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 186.112
Left Arm D1 momentum : 0.557003
Left Arm D1 NMR : 0.206331
Left Arm Q3 power supply current : 221.802
Left Arm Q3 momentum : 0.557126
Left Arm Q3 gauss meter : 0.11023
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 3.94511
Current on Unser monitor : 14.9973
Current on Upstream bcm : 3.96317
Current on Downstream bcm : 3.79011
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 57.7882
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.598291
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 15.86
haSC200_6_Sensor_3_R : 2.94
haSC200_6_Sensor_4_R : 39.73
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 0
haITC502_1_Sensor_3_R : 92.4
haITC502_4_Sensor_1_R : 94.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.75
haITC502_5_Sensor_2_R : 93.34
haITC502_5_Sensor_3_R : 267.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.87
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3614
HacR_VPM_LVDT:VALr :
HacR_HPE1313A:0_Ch58 : -0.560059
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.71875
HacR_alignROLL : -0.237229
HacR_alignPITCH : 0.00297144
HacR_alignHPT : 1.17385
HacL_HPM_LVDT:VALr : -2466
HacL_VPM_LVDT:VALr : -419
HacL_HPE1313A:0_Ch58 : -0.328125
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.263184
HacL_alignROLL : 0.0994453
HacL_alignPITCH : 0.0486702
HacL_alignHPT : -1.05426
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 24
Right Arm Scattering Angle : 28.3274
Left Arm Angle Floor Angle : 61
Left Arm Angle Vernier : -73
Left Arm Scattering Angle : 60.4074
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 200
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88