User name adev
Log entry time 11:54:15 on January 12, 2001
Entry number 54438
keyword=Start_Run_1242_Tar=absence,Type=Other,Lmom=0.557,Rmom=1.020,Ene=1.173,Angle_R=28.327,Angle_L=60.405
Beginning-of-run EPICS data for Run Number 1242 at Fri Jan 12 11:53:57 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1000,ps2=1000,ps3=1000,ps4=1000,ps5=3,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.21
Right Arm Q1 momentum : 0.838118
Right Arm Q1 gauss meter : 0
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.513
Right Arm Q2 momentum : 0.837688
Right Arm Q2 gauss meter : 0.18967
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.611
Right Arm D1 momentum : 0.838
Right Arm D1 NMR : 0.310972
Right Arm Q3 power supply current : 333.369
Right Arm Q3 momentum : 0.837802
Right Arm Q3 gauss meter : 0.14941
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.175
Left Arm Q1 momentum : 0.837629
Left Arm Q1 gauss meter : 0.0539
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 360.832
Left Arm Q2 momentum : 0.837975
Left Arm Q2 gauss meter : -0.19071
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 280.414
Left Arm D1 momentum : 0.837993
Left Arm D1 NMR : 0.310291
Left Arm Q3 power supply current : 333.637
Left Arm Q3 momentum : 0.838034
Left Arm Q3 gauss meter : 0.16725
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0371277
Current on Unser monitor : 11.6418
Current on Upstream bcm : 0.0402353
Current on Downstream bcm : 0.03402
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 123.259
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.561661
haBDSPOS : -44998
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.73
haSC200_6_Sensor_2_R : 15.56
haSC200_6_Sensor_3_R : 2.66
haSC200_6_Sensor_4_R : 39.5
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 92.18
haITC502_4_Sensor_1_R : 94.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.72
haITC502_5_Sensor_3_R : 272.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.13
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4479
HacR_VPM_LVDT:VALr : 550
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.945312
HacR_alignROLL : -0.467045
HacR_alignPITCH : -0.016196
HacR_alignHPT : 2.24883
HacL_HPM_LVDT:VALr : -6949
HacL_VPM_LVDT:VALr : -354
HacL_HPE1313A:0_Ch58 : -0.22998
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.205566
HacL_alignROLL : 0.150325
HacL_alignPITCH : -0.0387252
HacL_alignHPT : 3.96045
Right Arm Angle Floor Angle : 41
Right Arm Angle Vernier : 44
Right Arm Scattering Angle : 41.4354
Left Arm Angle Floor Angle : 42
Left Arm Angle Vernier : -64
Left Arm Scattering Angle : 41.4253
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 500
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88