Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 12:37:11 on January 12, 2001
Entry number 54441
keyword=Start_Run_1243_Tar=absence,Type=Optics,Lmom=0.557,Rmom=1.020,Ene=1.173,Angle_R=28.327,Angle_L=60.405
Beginning-of-run EPICS data for Run Number 1243 at Fri Jan 12 12:36:50 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1000,ps2=1000,ps3=1000,ps4=1000,ps5=3,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.21
Right Arm Q1 momentum : 0.838118
Right Arm Q1 gauss meter : -0.015767
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.657
Right Arm Q2 momentum : 0.838021
Right Arm Q2 gauss meter : 0.18964
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.619
Right Arm D1 momentum : 0.838002
Right Arm D1 NMR : 0.310973
Right Arm Q3 power supply current : 333.393
Right Arm Q3 momentum : 0.837864
Right Arm Q3 gauss meter : 0.14945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.105
Left Arm Q1 momentum : 0.837536
Left Arm Q1 gauss meter : 0.05394
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 360.976
Left Arm Q2 momentum : 0.838309
Left Arm Q2 gauss meter : -0.19075
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 280.413
Left Arm D1 momentum : 0.837995
Left Arm D1 NMR : 0.310292
Left Arm Q3 power supply current : 333.604
Left Arm Q3 momentum : 0.837945
Left Arm Q3 gauss meter : 0.16729
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.04189
Current on Unser monitor : 15.5953
Current on Upstream bcm : 5.15202
Current on Downstream bcm : 4.93176
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.97535
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.588523
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 34.705
haL3_Fan_frequency_R : 31.7303
haSC200_6_Sensor_1_R : 241.79
haSC200_6_Sensor_2_R : 15.63
haSC200_6_Sensor_3_R : 2.74
haSC200_6_Sensor_4_R : 39.61
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 92.75
haITC502_4_Sensor_1_R : 94.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.83
haITC502_5_Sensor_3_R : 269.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.01
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4494
HacR_VPM_LVDT:VALr : 554
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.949219
HacR_alignROLL : -0.468961
HacR_alignPITCH : -0.0167112
HacR_alignHPT : 2.26447
HacL_HPM_LVDT:VALr : -6930
HacL_VPM_LVDT:VALr : -337
HacL_HPE1313A:0_Ch58 : -0.229004
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.20752
HacL_alignROLL : 0.149586
HacL_alignPITCH : -0.0397428
HacL_alignHPT : 3.93846
Right Arm Angle Floor Angle : 41
Right Arm Angle Vernier : 44
Right Arm Scattering Angle : 41.4352
Left Arm Angle Floor Angle : 42
Left Arm Angle Vernier : -64
Left Arm Scattering Angle : 41.4254
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 212
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88