User name adev
Log entry time 12:53:27 on January 12, 2001
Entry number 54446
keyword=End_of_Run_1245
End-of-run EPICS data for Run Number 1245 at Fri Jan 12 12:53:03 EST 2001
Right Arm D1 momentum : 0.837999
Right Arm arm angle : 41.4352
Left Arm D1 momentum : 0.837994
Left Arm arm angle : 41.4254
Tiefenbach Hall A energy : 1173.62
Right Arm arm mispointing (HPT) : 2.27458
Left Arm arm mispointing (HPT) : 3.94066
Right Arm Q1 power supply current : 630.175
Right Arm Q1 momentum : 0.837978
Right Arm Q1 gauss meter : -0.015767
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.661
Right Arm Q2 momentum : 0.837803
Right Arm Q2 gauss meter : 0.18964
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.618
Right Arm D1 momentum : 0.838002
Right Arm D1 NMR : 0.310973
Right Arm Q3 power supply current : 333.455
Right Arm Q3 momentum : 0.83802
Right Arm Q3 gauss meter : 0.14939
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.175
Left Arm Q1 momentum : 0.837536
Left Arm Q1 gauss meter : 0.05393
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 360.705
Left Arm Q2 momentum : 0.837681
Left Arm Q2 gauss meter : -0.19072
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 280.411
Left Arm D1 momentum : 0.837995
Left Arm D1 NMR : 0.310292
Left Arm Q3 power supply current : 333.744
Left Arm Q3 momentum : 0.838302
Left Arm Q3 gauss meter : 0.16728
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.23063
Current on Unser monitor : 14.8692
Current on Upstream bcm : 4.37725
Current on Downstream bcm : 4.16171
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.20847
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.62
Tiefenbach Hall C energy : 3394.99
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00154722
IPM1H04A.XPOS : 0.289484
IPM1H04A.YPOS : 0.797482
IPM1H04B.XPOS : -0.0769143
IPM1H04B.YPOS : -0.0583461
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4501
HacR_VPM_LVDT:VALr : 557
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.949219
HacR_alignROLL : -0.469126
HacR_alignPITCH : -0.0165119
HacR_alignHPT : 2.27464
HacL_HPM_LVDT:VALr : -6932
HacL_VPM_LVDT:VALr : -337
HacL_HPE1313A:0_Ch58 : -0.228027
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.207031
HacL_alignROLL : 0.150028
HacL_alignPITCH : -0.0406159
HacL_alignHPT : 3.94203
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 22.82
haH2_P_Exhaust_R : 23.31
haH2_P_Fill_Bottle_R : 23.36
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.04
haD2_P_Exhaust_R : 20.66
haD2_P_Fill_Bottle_R : 40.73
haD2_DP_Fill_Exhaust_R : 0.0764
haSC200_6_Sensor_1_R : 241.96
haSC200_6_Sensor_2_R : 15.79
haSC200_6_Sensor_3_R : 2.86
haSC200_6_Sensor_4_R : 39.66
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 92.15
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 18.95
haITC502_4_Sensor_1_R : 94.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.79
haITC502_5_Sensor_3_R : 269.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.95
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 212
Laser power Hall A : 57
Half-wave plate (off=out) : ON