User name adev
Log entry time 16:16:15 on January 12, 2001
Entry number 54494
keyword=Start_Run_1266_Tar=LH2-15cm,Type=singles,Lmom=0.838,Rmom=0.838,Ene=1.173,Angle_R=41.435,Angle_L=41.425
Beginning-of-run EPICS data for Run Number 1266 at Fri Jan 12 16:15:55 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1000,ps3=2,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.28
Right Arm Q1 momentum : 0.838211
Right Arm Q1 gauss meter : -0.015767
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.65
Right Arm Q2 momentum : 0.838004
Right Arm Q2 gauss meter : 0.18961
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.618
Right Arm D1 momentum : 0.838002
Right Arm D1 NMR : 0.310972
Right Arm Q3 power supply current : 333.431
Right Arm Q3 momentum : 0.83796
Right Arm Q3 gauss meter : 0.14941
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.385
Left Arm Q1 momentum : 0.837909
Left Arm Q1 gauss meter : 0.05397
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 360.681
Left Arm Q2 momentum : 0.837624
Left Arm Q2 gauss meter : -0.1907
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 280.413
Left Arm D1 momentum : 0.837995
Left Arm D1 NMR : 0.310292
Left Arm Q3 power supply current : 333.612
Left Arm Q3 momentum : 0.837879
Left Arm Q3 gauss meter : 0.16727
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.79681
Current on Unser monitor : 15.449
Current on Upstream bcm : 4.84417
Current on Downstream bcm : 4.74945
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 76.4388
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 3.06227
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 36.3086
haL3_Fan_frequency_R : 31.77
haSC200_6_Sensor_1_R : 241.98
haSC200_6_Sensor_2_R : 15.69
haSC200_6_Sensor_3_R : 2.79
haSC200_6_Sensor_4_R : 39.61
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 91.98
haITC502_4_Sensor_1_R : 94.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.83
haITC502_5_Sensor_3_R : 267.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.87
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4509
HacR_VPM_LVDT:VALr : 550
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.95166
HacR_alignROLL : -0.472357
HacR_alignPITCH : -0.0194707
HacR_alignHPT : 2.28432
HacL_HPM_LVDT:VALr : -6944
HacL_VPM_LVDT:VALr : -350
HacL_HPE1313A:0_Ch58 : -0.227051
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.208496
HacL_alignROLL : 0.148775
HacL_alignPITCH : -0.0415614
HacL_alignHPT : 3.95449
Right Arm Angle Floor Angle : 41
Right Arm Angle Vernier :
Right Arm Scattering Angle : 41.4351
Left Arm Angle Floor Angle : 42
Left Arm Angle Vernier : -64
Left Arm Scattering Angle : 41.4253
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 218
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88