User name adev
Log entry time 18:32:05 on January 12, 2001
Entry number 54506
keyword=End_of_Run_1269
****************************
Run Number: 1269
End of Run Comment:
RunType=Cosmic,Tar=carbon,Rad=out,comment=runstart.tcl change test,Lmom=0.521,Rmom=0.953,Ene=1.173,Angle_R=28.349,Angle_L=60.18
Time of run = 0.57639973 min
Av. current (on 3x) = 5.8986842 uA
Av. current (on 1x) = 5.9015757 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 0.2041 | 0.2040 | 0.2047
up-down (mC)| 0.0078 | 0.0034 | 0.0051
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 1329.0256 Hz | 225308.8 /mC | 664.513 Hz | 45963 | 2 | 225198.4 /mC
2 | 1416.8408 Hz | 240196.1 /mC | 1.417 Hz | 49000 | 1000 | 240078.4 /mC
3 | 1306.2405 Hz | 221446.1 /mC | 653.120 Hz | 45175 | 2 | 221337.6 /mC
4 | 1589.3195 Hz | 269436.3 /mC | 1.589 Hz | 54965 | 1000 | 269304.3 /mC
5 | 12.028689 Hz | 2039.2 /mC | 12.029 Hz | 416 | 1 | 2038.2 /mC
8 | 1024.0 Hz | 173598.0 /mC | 0.016 Hz | 35414 | 65535 | 173513.0 /mC
output 1134.774 Hz
Av. deadtime from accepted triggers = 0.1407
Av. deadtime from gated scalers = 0.2194
Accepted triggers = 39245.00000
Rate of Left Arm Pulser for electronic DT = 10.149207
Rate of Right Arm Pulser for electronic DT = 9.8600555
Rate of Left Arm Pulser&trig for electronic DT = 10.149207
Rate of Right Arm Pulser&trig for electronic DT = 9.8600555
Left Arm Electronic DT = 0.0
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 5946.5676
Rate of Right Arm Strobe = 4258.0404
Signal | Charge (C)
upstream | 0.0002080
upstream 3x | 0.0002057
upstream 10x| 0.0002073
downstream | 0.0002002
downstream 3x | 0.0002023
downstream 10x| 0.0002022
****************************
End-of-run EPICS data for Run Number 1269 at Fri Jan 12 18:31:48 EST 2001
Right Arm D1 momentum : 0.952998
Right Arm arm angle : 28.3493
Left Arm D1 momentum : 0.521003
Left Arm arm angle : 60.1801
Tiefenbach Hall A energy : 1173.62
Right Arm arm mispointing (HPT) : -2.0602
Left Arm arm mispointing (HPT) : -1.31591
Right Arm Q1 power supply current : 716.625
Right Arm Q1 momentum : 0.953041
Right Arm Q1 gauss meter : -0.017893
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 410.013
Right Arm Q2 momentum : 0.952706
Right Arm Q2 gauss meter : 0.2156
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 326.958
Right Arm D1 momentum : 0.953001
Right Arm D1 NMR : 0.353647
Right Arm Q3 power supply current : 379.182
Right Arm Q3 momentum : 0.952937
Right Arm Q3 gauss meter : 0.16991
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 391.93
Left Arm Q1 momentum : 0.520954
Left Arm Q1 gauss meter : 0.03387
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 224.155
Left Arm Q2 momentum : 0.520564
Left Arm Q2 gauss meter : -0.11881
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 173.68
Left Arm D1 momentum : 0.521003
Left Arm D1 NMR : 0.193011
Left Arm Q3 power supply current : 207.411
Left Arm Q3 momentum : 0.520977
Left Arm Q3 gauss meter : 0.10436
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.9134
Current on Unser monitor : 16.7883
Current on Upstream bcm : 5.98351
Current on Downstream bcm : 5.88096
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 79.1898
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.62
Tiefenbach Hall C energy : 3395.21
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.002969
IPM1H04A.XPOS : 0.219648
IPM1H04A.YPOS : 0.207898
IPM1H04B.XPOS : 0.0191752
IPM1H04B.YPOS : 0.158093
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -703
HacR_VPM_LVDT:VALr : 160
HacR_HPE1313A:0_Ch58 : -0.555664
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.759277
HacR_alignROLL : -0.278695
HacR_alignPITCH : -0.0014509
HacR_alignHPT : -2.05989
HacL_HPM_LVDT:VALr : -2232
HacL_VPM_LVDT:VALr : -356
HacL_HPE1313A:0_Ch58 : -0.316406
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.26416
HacL_alignROLL : 0.098491
HacL_alignPITCH : 0.038262
HacL_alignHPT : -1.31566
haBDSPOS : 708450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 22.41
haH2_P_Exhaust_R : 22.87
haH2_P_Fill_Bottle_R : 22.91
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.02
haD2_P_Exhaust_R : 20.28
haD2_P_Fill_Bottle_R : 40
haD2_DP_Fill_Exhaust_R : 0.0763
haSC200_6_Sensor_1_R : 242.11
haSC200_6_Sensor_2_R : 15.82
haSC200_6_Sensor_3_R : 2.91
haSC200_6_Sensor_4_R : 39.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 91.36
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.94
haITC502_4_Sensor_1_R : 94.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.79
haITC502_5_Sensor_3_R : 272.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.09
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 231
Laser power Hall A : 57
Half-wave plate (off=out) : ON