User name adev
Log entry time 00:13:54 on January 17, 2001
Entry number 54865
keyword=Start_Run_1397_RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=KIN17,mode=coincidence,Lmom=3.359,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=27.345
Beginning-of-run EPICS data for Run Number 1397 at Wed Jan 17 00:13:44 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1000,ps3=2,ps4=2000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.16
Right Arm Q1 momentum : 2.98983
Right Arm Q1 gauss meter : -0.05584
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1286.78
Right Arm Q2 momentum : 2.98996
Right Arm Q2 gauss meter : 0.6756
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.63
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.91
Right Arm Q3 momentum : 2.99041
Right Arm Q3 gauss meter : 0.5335
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.28
Left Arm Q1 momentum : 3.35926
Left Arm Q1 gauss meter : 0.21424
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.4
Left Arm Q2 momentum : 3.35902
Left Arm Q2 gauss meter : -0.7607
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.04
Left Arm D1 momentum : 3.359
Left Arm D1 NMR : 1.24405
Left Arm Q3 power supply current : 1337.2
Left Arm Q3 momentum : 3.35881
Left Arm Q3 gauss meter : 0.6664
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 35.8134
Current on Unser monitor : 46.3761
Current on Upstream bcm : 35.815
Current on Downstream bcm : 35.8117
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 80.3034
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 4.64713
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 241.9
haSC200_6_Sensor_2_R : 15.54
haSC200_6_Sensor_3_R : 2.74
haSC200_6_Sensor_4_R : 39.65
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 94.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 270.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.18
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -934
HacR_VPM_LVDT:VALr : 25
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.770508
HacR_alignROLL : -0.289539
HacR_alignPITCH : -0.00818339
HacR_alignHPT : -1.79625
HacL_HPM_LVDT:VALr : -7983
HacL_VPM_LVDT:VALr : 926
HacL_HPE1313A:0_Ch58 : -0.152832
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.241699
HacL_alignROLL : 0.118525
HacL_alignPITCH : -0.1077
HacL_alignHPT : 5.12883
Right Arm Angle Floor Angle : 31
Right Arm Angle Vernier : -15.1
Right Arm Scattering Angle : 31.1221
Left Arm Angle Floor Angle : 27.5
Left Arm Angle Vernier : 10.2
Left Arm Scattering Angle : 27.345
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 254
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88