User name adev
Log entry time 17:20:34 on January 17, 2001
Entry number 54917
keyword=End_of_Run_1414
****************************
Run Number: 1414
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=KIN17,mode=coincidence,Lmom=3.359,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=27.345
Time of run = 80.768507 min
Av. current (on 3x) = 25.126997 uA
Av. current (on 1x) = 25.075595 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 121.5191 | 121.7682 | 122.0644
up-down (mC)| 3.1732 | 2.6928 | 3.3771
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 502.16417 Hz | 19985.0 /mC | 100.433 Hz | 2433543 | 5 | 20026.0 /mC
2 | 44753.226 Hz | 1781081.3 /mC | 8.951 Hz | 216879070 | 5000 | 1784732.4 /mC
3 | 753.49707 Hz | 29987.5 /mC | 83.722 Hz | 3651530 | 9 | 30049.0 /mC
4 | 75954.182 Hz | 3022811.8 /mC | 8.439 Hz | 368082350 | 9000 | 3029008.2 /mC
5 | 14.545273 Hz | 578.9 /mC | 14.545 Hz | 70488 | 1 | 580.1 /mC
Trigger 5 corrected for pulser:
5 (phys) | 4.373817 Hz | 174.1 /mC | 4.374 Hz | 21196.001 | 1 | 174.4 /mC
8 | 1024.0 Hz | 40753.0 /mC | 0.016 Hz | 4962417 | 65535 | 40836.5 /mC
output 205.909 Hz
Av. deadtime from accepted triggers = 0.0268
Av. deadtime from gated scalers = 0.0549
Accepted triggers = 997859.00000
Rate of Left Arm Pulser for electronic DT = 10.171456
Rate of Right Arm Pulser for electronic DT = 10.169393
Rate of Left Arm Pulser&trig for electronic DT = 10.171456
Rate of Right Arm Pulser&trig for electronic DT = 10.169393
Left Arm Electronic DT = 0.0
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 127996.56
Rate of Right Arm Strobe = 67285.472
Signal | Charge (C)
upstream | 0.1231057
upstream 3x | 0.1231146
upstream 10x| 0.1237529
downstream | 0.1199325
downstream 3x | 0.1204218
downstream 10x| 0.1203758
****************************
End-of-run EPICS data for Run Number 1414 at Wed Jan 17 17:20:22 EST 2001
Right Arm D1 momentum : 2.99
Right Arm arm angle : 31.1218
Left Arm D1 momentum : 3.359
Left Arm arm angle : 27.3448
Tiefenbach Hall A energy : 5614.96
Right Arm arm mispointing (HPT) : -1.74676
Left Arm arm mispointing (HPT) : 5.16548
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : -0.05584
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1286.62
Right Arm Q2 momentum : 2.98959
Right Arm Q2 gauss meter : 0.6755
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.63
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.73
Right Arm Q3 momentum : 2.98996
Right Arm Q3 gauss meter : 0.5336
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.31
Left Arm Q1 momentum : 3.35931
Left Arm Q1 gauss meter : 0.21422
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.48
Left Arm Q2 momentum : 3.35922
Left Arm Q2 gauss meter : -0.7608
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.03
Left Arm D1 momentum : 3.359
Left Arm D1 NMR : 1.24405
Left Arm Q3 power supply current : 1337.26
Left Arm Q3 momentum : 3.35895
Left Arm Q3 gauss meter : 0.6666
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 30.3413
Current on Unser monitor : 40.5607
Current on Upstream bcm : 30.5367
Current on Downstream bcm : 30.5341
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 74.0635
MBSY1c Hall A Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
MBSY1c Bdl : 1.40413e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5614.96
Tiefenbach Hall C energy : 3395.48
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.000742733
IPM1H04A.XPOS : -0.233609
IPM1H04A.YPOS : -0.0890098
IPM1H04B.XPOS : -0.0435095
IPM1H04B.YPOS : -0.193555
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -981
HacR_VPM_LVDT:VALr : 5
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.768555
HacR_alignROLL : -0.287508
HacR_alignPITCH : -0.0104938
HacR_alignHPT : -1.7448
HacL_HPM_LVDT:VALr : -8014
HacL_VPM_LVDT:VALr : 916
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.246094
HacL_alignROLL : 0.114621
HacL_alignPITCH : -0.10952
HacL_alignHPT : 5.16646
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 38
haL3_Fan_frequency_R : 49.5
haH2_P_Fill_Target_R : 23.81
haH2_P_Exhaust_R : 24.27
haH2_P_Fill_Bottle_R : 24.13
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.15
haD2_P_Exhaust_R : 21.49
haD2_P_Fill_Bottle_R : 42.43
haD2_DP_Fill_Exhaust_R : 0.0796
haSC200_6_Sensor_1_R : 241.79
haSC200_6_Sensor_2_R : 15.28
haSC200_6_Sensor_3_R : 2.63
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 89.11
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.07
haITC502_4_Sensor_1_R : 93.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22.1
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 269.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 97.36
haITC502_6_Sensor_3_R : 28.08
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.616992
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 218
Laser power Hall A : 57
Half-wave plate (off=out) : OFF