User name adev
Log entry time 21:39:32 on January 17, 2001
Entry number 54924
keyword=End_of_Run_1418
****************************
Run Number: 1418
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=KIN17,mode=coincidence,Lmom=3.359,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=27.345
Time of run = 93.954867 min
Av. current (on 3x) = 21.715923 uA
Av. current (on 1x) = 21.670813 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 122.1647 | 122.4190 | 122.7237
up-down (mC)| 3.1466 | 2.5820 | 3.3009
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 427.87317 Hz | 19703.2 /mC | 85.575 Hz | 2412046 | 5 | 19744.2 /mC
2 | 38880.287 Hz | 1790404.5 /mC | 7.776 Hz | 219179530 | 5000 | 1794131.4 /mC
3 | 637.80766 Hz | 29370.5 /mC | 70.868 Hz | 3595508 | 9 | 29431.6 /mC
4 | 65978.824 Hz | 3038269.4 /mC | 7.331 Hz | 371941900 | 9000 | 3044593.9 /mC
5 | 13.97107 Hz | 643.4 /mC | 13.971 Hz | 78759 | 1 | 644.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 3.800406 Hz | 175.0 /mC | 3.800 Hz | 21423.997 | 1 | 175.4 /mC
8 | 1024.0 Hz | 47154.3 /mC | 0.016 Hz | 5772587 | 65535 | 47252.5 /mC
output 176.820 Hz
Av. deadtime from accepted triggers = 0.0241
Av. deadtime from gated scalers = 0.0519
Accepted triggers = 996788.00000
Rate of Left Arm Pulser for electronic DT = 10.170664
Rate of Right Arm Pulser for electronic DT = 10.16889
Rate of Left Arm Pulser&trig for electronic DT = 10.170486
Rate of Right Arm Pulser&trig for electronic DT = 10.16889
Left Arm Electronic DT = 1.7441353e-05
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 111182.65
Rate of Right Arm Strobe = 58350.04
Signal | Charge (C)
upstream | 0.1237380
upstream 3x | 0.1237100
upstream 10x| 0.1243742
downstream | 0.1205914
downstream 3x | 0.1211280
downstream 10x| 0.1210733
****************************
End-of-run EPICS data for Run Number 1418 at Wed Jan 17 21:39:22 EST 2001
Right Arm D1 momentum : 2.99
Right Arm arm angle : 31.1217
Left Arm D1 momentum : 3.35899
Left Arm arm angle : 27.3447
Tiefenbach Hall A energy : 5614.96
Right Arm arm mispointing (HPT) : -1.72612
Left Arm arm mispointing (HPT) : 5.17868
Right Arm Q1 power supply current : 2248.12
Right Arm Q1 momentum : 2.98978
Right Arm Q1 gauss meter : -0.05583
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1286.99
Right Arm Q2 momentum : 2.99046
Right Arm Q2 gauss meter : 0.6755
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.64
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.82
Right Arm Q3 momentum : 2.99019
Right Arm Q3 gauss meter : 0.5335
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.31
Left Arm Q1 momentum : 3.35931
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.56
Left Arm Q2 momentum : 3.35941
Left Arm Q2 gauss meter : -0.7607
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.03
Left Arm D1 momentum : 3.35899
Left Arm D1 NMR : 1.24405
Left Arm Q3 power supply current : 1337.13
Left Arm Q3 momentum : 3.35861
Left Arm Q3 gauss meter : 0.6666
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0387475
Current on Unser monitor : 10.124
Current on Upstream bcm : 0.04485
Current on Downstream bcm : 0.032645
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 13.8221
MBSY1c Hall A Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
MBSY1c Bdl : 1.40413e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5614.96
Tiefenbach Hall C energy : 3394.84
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 2.76645
IPM1H04A.XPOS : 0.00401684
IPM1H04A.YPOS : 0.264776
IPM1H04B.XPOS : -0.0229849
IPM1H04B.YPOS : 0.508676
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1000
HacR_VPM_LVDT:VALr : -10
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.766602
HacR_alignROLL : -0.28597
HacR_alignPITCH : -0.011009
HacR_alignHPT : -1.72553
HacL_HPM_LVDT:VALr : -8026
HacL_VPM_LVDT:VALr : 904
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.246582
HacL_alignROLL : 0.114835
HacL_alignPITCH : -0.110178
HacL_alignHPT : 5.17753
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 38
haL3_Fan_frequency_R : 49.5
haH2_P_Fill_Target_R : 23.5
haH2_P_Exhaust_R : 23.96
haH2_P_Fill_Bottle_R : 23.84
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.16
haD2_P_Exhaust_R : 21.06
haD2_P_Fill_Bottle_R : 41.52
haD2_DP_Fill_Exhaust_R : 0.08
haSC200_6_Sensor_1_R : 242.05
haSC200_6_Sensor_2_R : 15.31
haSC200_6_Sensor_3_R : 2.71
haSC200_6_Sensor_4_R : 39.6
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 89.69
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.06
haITC502_4_Sensor_1_R : 93.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 270
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 98.27
haITC502_6_Sensor_3_R : 28.09
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 145
Laser power Hall A : 57
Half-wave plate (off=out) : OFF