• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 06:12:58 on January 19, 2001

    Entry number 55125

    keyword=End_of_Run_1498
    ****************************
     Run Number: 1498
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=Kin16,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=31.11
    
    
    Time of run = 12.039551 min
    Av. current (on 3x) = 13.15373 uA
    Av. current (on 1x) = 13.131165 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    9.4856  |    9.5019  |    9.5281
    up-down    (mC)|    0.2687  |    0.2038  |    0.2643
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 57.095153 Hz  |      4340.6 /mC  |   57.095 Hz  |     41244  |     1   |      4348.1 /mC
        2      | 6093.0208 Hz  |    463216.2 /mC  |    6.093 Hz  |   4401434  |  1000   |    464012.2 /mC
        3      | 69.475183 Hz  |      5281.8 /mC  |   69.475 Hz  |     50187  |     1   |      5290.9 /mC
        4      | 9474.3678 Hz  |    720279.9 /mC  |    4.737 Hz  |   6844028  |  2000   |    721517.7 /mC
        5      | 10.29385 Hz  |       782.6 /mC  |   10.294 Hz  |      7436  |     1   |       783.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.12182 Hz  |         9.3 /mC  |    0.122 Hz  | 87.999664  |     1   |         9.3 /mC
        8    | 1024.0 Hz  |     77848.6 /mC  |    0.016 Hz  |    739710  | 65535   |     77982.4 /mC
        output                       120.767 Hz
    Av. deadtime from accepted triggers = 0.0500
    Av. deadtime from gated scalers = 0.0664
    Accepted triggers  =  87239.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17203
    Rate of Right Arm Pulser for electronic DT  = 10.154033
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17203
    Rate of Right Arm Pulser&trig for electronic DT  = 10.154033
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 15590.061
    Rate of Right Arm Strobe  = 8669.7503
        Signal     |    Charge   (C)   
       upstream    |    0.0096200     
       upstream 3x |    0.0096038     
       upstream 10x|    0.0096602     
      downstream   |    0.0093513   
     downstream 3x |    0.0094000   
     downstream 10x|    0.0093959    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1498 at Fri Jan 19 06:12:48 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1216
    Left Arm D1 momentum                      : 2.98999
    Left Arm arm angle                        : 31.0739
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : -1.71856
    Left Arm arm mispointing (HPT)            : 5.29525
    Right Arm Q1 power supply current        : 2248.26
    Right Arm Q1 momentum                    : 2.98997
    Right Arm Q1 gauss meter                 : -0.05583
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1286.82
    Right Arm Q2 momentum                    : 2.99006
    Right Arm Q2 gauss meter                 : 0.6755
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1072.63
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.73
    Right Arm Q3 momentum                    : 2.98995
    Right Arm Q3 gauss meter                 : 0.5334
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2249.59
    Left Arm Q1 momentum                      : 2.99016
    Left Arm Q1 gauss meter                   : 0.19081
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1287.56
    Left Arm Q2 momentum                      : 2.99016
    Left Arm Q2 gauss meter                   : -0.6777
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1045.77
    Left Arm D1 momentum                      : 2.98999
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.38
    Left Arm Q3 momentum                      : 2.99
    Left Arm Q3 gauss meter                   : 0.5938
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0403401
    Current on Unser monitor                : 11.6243
    Current on Upstream bcm                 : 0.0471944
    Current on Downstream bcm               : 0.0336997
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.00142881
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3394.85
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -1006
     HacR_VPM_LVDT:VALr                     : 45
     HacR_HPE1313A:0_Ch58                   : -0.542969
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.769043
     HacR_alignROLL                         : -0.287823
     HacR_alignPITCH                        : -0.012937
     HacR_alignHPT                          : -1.71775
     HacL_HPM_LVDT:VALr                     : -8112
     HacL_VPM_LVDT:VALr                     : 691
     HacL_HPE1313A:0_Ch58                   : -0.148926
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.263672
     HacL_alignROLL                         : 0.0993036
     HacL_alignPITCH                        : -0.111851
     HacL_alignHPT                          : 5.29489
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 65.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 23.75
    haH2_P_Exhaust_R                         : 23.97
    haH2_P_Fill_Bottle_R                     : 24.03
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.76
    haD2_P_Exhaust_R                         : 21.39
    haD2_P_Fill_Bottle_R                     : 42.22
    haD2_DP_Fill_Exhaust_R                   : 0.077
    haSC200_6_Sensor_1_R                     : 241.66
    haSC200_6_Sensor_2_R                     : 15.19
    haSC200_6_Sensor_3_R                     : 2.71
    haSC200_6_Sensor_4_R                     : 39.55
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 89.09
    haITC502_2_Sensor_1_R                    : 19.01
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 93
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 267.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 97.22
    haITC502_6_Sensor_3_R                    : 28.01
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 268
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF