    User name adev

    Log entry time 13:04:44 on January 19, 2001

    Entry number 55150

    keyword=End_of_Run_1507
    ****************************
     Run Number: 1507
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=Kin16,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=31.074
    
    Time of run = 15.608757 min
    Av. current (on 3x) = 27.325901 uA
    Av. current (on 1x) = 27.26429 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   25.5337  |   25.5914  |   25.6500
    up-down    (mC)|    0.6855  |    0.5752  |    0.7292
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 541.31474 Hz  |     19809.6 /mC  |  541.315 Hz  |    506955  |     1   |     19854.3 /mC
        2      | 48275.38 Hz  |   1766652.8 /mC  |   48.275 Hz  |  45211119  |  1000   |   1770645.0 /mC
        3      | 739.7557 Hz  |     27071.6 /mC  |  739.756 Hz  |    692800  |     1   |     27132.8 /mC
        4      | 77909.591 Hz  |   2851126.2 /mC  |   38.955 Hz  |  72964310  |  2000   |   2857569.0 /mC
        5      | 11.746612 Hz  |       429.9 /mC  |   11.747 Hz  |     11001  |     1   |       430.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.574971 Hz  |        57.6 /mC  |    1.575 Hz  | 1474.9999  |     1   |        57.8 /mC
        8    | 1024.0 Hz  |     37473.6 /mC  |    0.016 Hz  |    959002  | 65535   |     37558.3 /mC
        output                      1076.975 Hz
    Av. deadtime from accepted triggers = 0.2061
    Av. deadtime from gated scalers = 0.2113
    Accepted triggers  = 1008614.00000
    Rate of Left Arm Pulser for electronic DT  = 10.171641
    Rate of Right Arm Pulser for electronic DT  = 10.15776
    Rate of Left Arm Pulser&trig for electronic DT  = 10.171641
    Rate of Right Arm Pulser&trig for electronic DT  = 10.15776
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 132093.44
    Rate of Right Arm Strobe  = 72626.261
        Signal     |    Charge   (C)   
       upstream    |    0.0258764     
       upstream 3x |    0.0258790     
       upstream 10x|    0.0260146     
      downstream   |    0.0251909   
     downstream 3x |    0.0253038   
     downstream 10x|    0.0252854    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1507 at Fri Jan 19 13:04:33 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1216
    Left Arm D1 momentum                      : 2.99
    Left Arm arm angle                        : 31.0739
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : -1.71881
    Left Arm arm mispointing (HPT)            : 5.29133
    Right Arm Q1 power supply current        : 2248.26
    Right Arm Q1 momentum                    : 2.98997
    Right Arm Q1 gauss meter                 : -0.05584
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1286.77
    Right Arm Q2 momentum                    : 2.98993
    Right Arm Q2 gauss meter                 : 0.6755
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1072.64
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.6
    Right Arm Q3 momentum                    : 2.98962
    Right Arm Q3 gauss meter                 : 0.5334
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2249.59
    Left Arm Q1 momentum                      : 2.99016
    Left Arm Q1 gauss meter                   : 0.1908
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1287.61
    Left Arm Q2 momentum                      : 2.99026
    Left Arm Q2 gauss meter                   : -0.6776
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1045.78
    Left Arm D1 momentum                      : 2.98999
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.39
    Left Arm Q3 momentum                      : 2.99005
    Left Arm Q3 gauss meter                   : 0.5938
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.1042
    Current on Unser monitor                : 39.9599
    Current on Upstream bcm                 : 29.1206
    Current on Downstream bcm               : 29.0879
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 72.7895
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.7
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00715411
    IPM1H04A.XPOS                           : -0.117716
    IPM1H04A.YPOS                           : -0.215877
    IPM1H04B.XPOS                           : -0.0499102
    IPM1H04B.YPOS                           : 0.0254135
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617139
     HacR_HPM_LVDT:VALr                     : -1005
     HacR_VPM_LVDT:VALr                     : 54
     HacR_HPE1313A:0_Ch58                   : -0.543945
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.769043
     HacR_alignROLL                         : -0.286897
     HacR_alignPITCH                        : -0.0124218
     HacR_alignHPT                          : -1.71828
     HacL_HPM_LVDT:VALr                     : -8108
     HacL_VPM_LVDT:VALr                     : 708
     HacL_HPE1313A:0_Ch58                   : -0.149414
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.263672
     HacL_alignROLL                         : 0.0993745
     HacL_alignPITCH                        : -0.111052
     HacL_alignHPT                          : 5.29172
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 37.5
    haL3_Fan_frequency_R                     : 47
    haH2_P_Fill_Target_R                     : 24.6
    haH2_P_Exhaust_R                         : 25
    haH2_P_Fill_Bottle_R                     : 24.85
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.63
    haD2_P_Exhaust_R                         : 21.82
    haD2_P_Fill_Bottle_R                     : 43.09
    haD2_DP_Fill_Exhaust_R                   : 0.079
    haSC200_6_Sensor_1_R                     : 241.51
    haSC200_6_Sensor_2_R                     : 15
    haSC200_6_Sensor_3_R                     : 2.71
    haSC200_6_Sensor_4_R                     : 39.58
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 87.4
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 91.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 269
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 95.16
    haITC502_6_Sensor_3_R                    : 28.01
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617139
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 249
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF