• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 17:04:38 on January 19, 2001

    Entry number 55180

    keyword=End_of_Run_1520
    ****************************
     Run Number: 1520
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=Kin16,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=31.074
    
    
    Time of run = 25.085677 min
    Av. current (on 3x) = 40.398419 uA
    Av. current (on 1x) = 40.311981 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   60.6752  |   60.8053  |   60.9178
    up-down    (mC)|    1.5463  |    1.3619  |    1.6928
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 293.61709 Hz  |      7268.0 /mC  |  293.617 Hz  |    441935  |     1   |      7283.6 /mC
        2      | 26971.143 Hz  |    667628.7 /mC  |   53.942 Hz  |  40595362  |   500   |    669060.2 /mC
        3      | 384.31758 Hz  |      9513.2 /mC  |  384.318 Hz  |    578452  |     1   |      9533.6 /mC
        4      | 43902.7 Hz  |   1086743.0 /mC  |   43.903 Hz  |  66079736  |  1000   |   1089073.2 /mC
        5      | 11.074048 Hz  |       274.1 /mC  |   11.074 Hz  |     16668  |     1   |       274.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.898919 Hz  |        22.3 /mC  |    0.899 Hz  | 1353.0002  |     1   |        22.3 /mC
        8    | 1024.0 Hz  |     25347.5 /mC  |    0.016 Hz  |   1541264  | 65535   |     25401.9 /mC
        output                       666.903 Hz
    Av. deadtime from accepted triggers = 0.1279
    Av. deadtime from gated scalers = 0.1364
    Accepted triggers  = 1003783.00000
    Rate of Left Arm Pulser for electronic DT  = 10.175129
    Rate of Right Arm Pulser for electronic DT  = 10.175129
    Rate of Left Arm Pulser&trig for electronic DT  = 10.175129
    Rate of Right Arm Pulser&trig for electronic DT  = 10.175129
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 73977.887
    Rate of Right Arm Strobe  = 40208.203
        Signal     |    Charge   (C)   
       upstream    |    0.0614484     
       upstream 3x |    0.0614863     
       upstream 10x|    0.0617642     
      downstream   |    0.0599021   
     downstream 3x |    0.0601244   
     downstream 10x|    0.0600714    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1520 at Fri Jan 19 17:04:27 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1216
    Left Arm D1 momentum                      : 2.99
    Left Arm arm angle                        : 31.0739
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : -1.71296
    Left Arm arm mispointing (HPT)            : 5.30041
    Right Arm Q1 power supply current        : 2248.26
    Right Arm Q1 momentum                    : 2.98997
    Right Arm Q1 gauss meter                 : -0.05583
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1286.78
    Right Arm Q2 momentum                    : 2.98995
    Right Arm Q2 gauss meter                 : 0.6754
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1072.63
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.8
    Right Arm Q3 momentum                    : 2.98976
    Right Arm Q3 gauss meter                 : 0.5335
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2249.66
    Left Arm Q1 momentum                      : 2.99025
    Left Arm Q1 gauss meter                   : 0.1908
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1287.52
    Left Arm Q2 momentum                      : 2.99005
    Left Arm Q2 gauss meter                   : -0.6777
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1045.77
    Left Arm D1 momentum                      : 2.99
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.25
    Left Arm Q3 momentum                      : 2.98968
    Left Arm Q3 gauss meter                   : 0.5938
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 43.9293
    Current on Unser monitor                : 54.3056
    Current on Upstream bcm                 : 43.9321
    Current on Downstream bcm               : 43.9264
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 44.1442
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3394.84
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00774999
    IPM1H04A.XPOS                           : -0.12329
    IPM1H04A.YPOS                           : -0.480812
    IPM1H04B.XPOS                           : -0.0377482
    IPM1H04B.YPOS                           : -0.0771737
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -1009
     HacR_VPM_LVDT:VALr                     : 58
     HacR_HPE1313A:0_Ch58                   : -0.543457
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.768555
     HacR_alignROLL                         : -0.287823
     HacR_alignPITCH                        : -0.0124882
     HacR_alignHPT                          : -1.71328
     HacL_HPM_LVDT:VALr                     : -8115
     HacL_VPM_LVDT:VALr                     : 707
     HacL_HPE1313A:0_Ch58                   : -0.148926
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.262695
     HacL_alignROLL                         : 0.099887
     HacL_alignPITCH                        : -0.111562
     HacL_alignHPT                          : 5.29908
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 38
    haL3_Fan_frequency_R                     : 47
    haH2_P_Fill_Target_R                     : 24.15
    haH2_P_Exhaust_R                         : 24.62
    haH2_P_Fill_Bottle_R                     : 24.44
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.56
    haD2_P_Exhaust_R                         : 21.92
    haD2_P_Fill_Bottle_R                     : 43.16
    haD2_DP_Fill_Exhaust_R                   : 0.0786
    haSC200_6_Sensor_1_R                     : 241.91
    haSC200_6_Sensor_2_R                     : 15.21
    haSC200_6_Sensor_3_R                     : 2.89
    haSC200_6_Sensor_4_R                     : 39.75
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 88.69
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 92.4
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 269.1
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 96.52
    haITC502_6_Sensor_3_R                    : 28.02
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 308
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF