• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 07:35:31 on January 20, 2001

    Entry number 55234

    keyword=End_of_Run_1543
    ****************************
     Run Number: 1543
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=Kin17,mode=singles,Lmom=2.547,Rmom=-2.547,Ene=5.617,Angle_R=36.676,Angle_L=36.656
    
    Time of run = 14.550895 min
    Av. current (on 3x) = 35.83949 uA
    Av. current (on 1x) = 35.764123 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   31.2240  |   31.2898  |   31.3586
    up-down    (mC)|    0.8026  |    0.7264  |    0.8911
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 576.2555 Hz  |     16078.8 /mC  |  576.255 Hz  |    503102  |     1   |     16112.7 /mC
        2      | 56872.961 Hz  |   1586879.7 /mC  |    9.479 Hz  |  49653150  |  6000   |   1590223.9 /mC
        3      | 909.09985 Hz  |     25365.9 /mC  |  909.100 Hz  |    793693  |     1   |     25419.3 /mC
        4      | 92145.204 Hz  |   2571052.3 /mC  |    9.215 Hz  |  80447712  | 10000   |   2576470.4 /mC
        5      | 10.22503 Hz  |       285.3 /mC  |   10.225 Hz  |      8927  |     1   |       285.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.05498 Hz  |         1.5 /mC  |    0.055 Hz  | 48.000117  |     1   |         1.5 /mC
        8    | 1024.0 Hz  |     28571.8 /mC  |    0.016 Hz  |    894007  | 65535   |     28632.0 /mC
        output                      1156.508 Hz
    Av. deadtime from accepted triggers = 0.2258
    Av. deadtime from gated scalers = 0.2295
    Accepted triggers  = 1009694.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17005
    Rate of Right Arm Pulser for electronic DT  = 10.17005
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17005
    Rate of Right Arm Pulser&trig for electronic DT  = 10.17005
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 157249.5
    Rate of Right Arm Strobe  = 86529.544
        Signal     |    Charge   (C)   
       upstream    |    0.0316253     
       upstream 3x |    0.0316530     
       upstream 10x|    0.0318041     
      downstream   |    0.0308227   
     downstream 3x |    0.0309266   
     downstream 10x|    0.0309130    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1543 at Sat Jan 20 07:35:20 EST 2001
    Right Arm D1 momentum                    : 2.547
    Right Arm arm angle                      : 36.6755
    Left Arm D1 momentum                      : 2.547
    Left Arm arm angle                        : 36.656
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : 2.14607
    Left Arm arm mispointing (HPT)            : 5.00045
    Right Arm Q1 power supply current        : 1915.13
    Right Arm Q1 momentum                    : 2.54694
    Right Arm Q1 gauss meter                 : -0.04763
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1096.13
    Right Arm Q2 momentum                    : 2.54697
    Right Arm Q2 gauss meter                 : 0.5756
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 898.046
    Right Arm D1 momentum                    : 2.547
    Right Arm D1 NMR                         : 0.945161
    Right Arm Q3 power supply current        : 1013.21
    Right Arm Q3 momentum                    : 2.54633
    Right Arm Q3 gauss meter                 : 0.4544
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1916.25
    Left Arm Q1 momentum                      : 2.54708
    Left Arm Q1 gauss meter                   : 0.1627
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1096.84
    Left Arm Q2 momentum                      : 2.54723
    Left Arm Q2 gauss meter                   : -0.5776
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.975
    Left Arm D1 momentum                      : 2.547
    Left Arm D1 NMR                           : 0.942748
    Left Arm Q3 power supply current          : 1013.92
    Left Arm Q3 momentum                      : 2.54679
    Left Arm Q3 gauss meter                   : 0.506
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 39.3511
    Current on Unser monitor                : 49.0696
    Current on Upstream bcm                 : 38.8793
    Current on Downstream bcm               : 39.5323
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 83.1704
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.69
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00395608
    IPM1H04A.XPOS                           : -0.128369
    IPM1H04A.YPOS                           : 0.0689376
    IPM1H04B.XPOS                           : 0.0744561
    IPM1H04B.YPOS                           : -0.10167
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4428
     HacR_VPM_LVDT:VALr                     : 412
     HacR_HPE1313A:0_Ch58                   : -0.53125
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.869141
     HacR_alignROLL                         : -0.388388
     HacR_alignPITCH                        : -0.0237101
     HacR_alignHPT                          : 2.14578
     HacL_HPM_LVDT:VALr                     : -7864
     HacL_VPM_LVDT:VALr                     : 420
     HacL_HPE1313A:0_Ch58                   : -0.16748
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.21875
     HacL_alignROLL                         : 0.139571
     HacL_alignPITCH                        : -0.0944612
     HacL_alignHPT                          : 4.99958
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 39
    haL3_Fan_frequency_R                     : 44
    haH2_P_Fill_Target_R                     : 23.75
    haH2_P_Exhaust_R                         : 24.16
    haH2_P_Fill_Bottle_R                     : 23.95
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.59
    haD2_P_Exhaust_R                         : 21.56
    haD2_P_Fill_Bottle_R                     : 42.51
    haD2_DP_Fill_Exhaust_R                   : 0.0783
    haSC200_6_Sensor_1_R                     : 241.66
    haSC200_6_Sensor_2_R                     : 15.01
    haSC200_6_Sensor_3_R                     : 2.78
    haSC200_6_Sensor_4_R                     : 39.73
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 87.79
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 91.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 268.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 95.36
    haITC502_6_Sensor_3_R                    : 27.99
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 301
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF