    User name adev

    Log entry time 11:07:18 on January 20, 2001

    Entry number 55261

    keyword=End_of_Run_1554
    ****************************
     Run Number: 1554
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=Kin17,mode=singles,Lmom=2.547,Rmom=-2.547,Ene=5.617,Angle_R=36.676,Angle_L=36.656
    
    Time of run = 13.609294 min
    Av. current (on 3x) = 37.928003 uA
    Av. current (on 1x) = 37.843869 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   30.9017  |   30.9704  |   31.0384
    up-down    (mC)|    0.7823  |    0.7208  |    0.8823
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 613.70439 Hz  |     16180.8 /mC  |  613.704 Hz  |    501125  |     1   |     16216.7 /mC
        2      | 60587.828 Hz  |   1597443.1 /mC  |   10.098 Hz  |  49473453  |  6000   |   1600994.5 /mC
        3      | 970.49367 Hz  |     25587.8 /mC  |  970.494 Hz  |    792464  |     1   |     25644.7 /mC
        4      | 98710.566 Hz  |   2602577.5 /mC  |    9.871 Hz  |  80602865  | 10000   |   2608363.5 /mC
        5      | 10.246674 Hz  |       270.2 /mC  |   10.247 Hz  |      8367  |     1   |       270.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.073479 Hz  |         1.9 /mC  |    0.073 Hz  | 60.000103  |     1   |         1.9 /mC
        8    | 1024.0 Hz  |     26998.5 /mC  |    0.016 Hz  |    836155  | 65535   |     27058.5 /mC
        output                      1231.149 Hz
    Av. deadtime from accepted triggers = 0.2276
    Av. deadtime from gated scalers = 0.2319
    Accepted triggers  = 1005304.00000
    Rate of Left Arm Pulser for electronic DT  = 10.173195
    Rate of Right Arm Pulser for electronic DT  = 10.157275
    Rate of Left Arm Pulser&trig for electronic DT  = 10.173195
    Rate of Right Arm Pulser&trig for electronic DT  = 10.157275
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 168716.82
    Rate of Right Arm Strobe  = 92276.126
        Signal     |    Charge   (C)   
       upstream    |    0.0312928     
       upstream 3x |    0.0313308     
       upstream 10x|    0.0314795     
      downstream   |    0.0305105   
     downstream 3x |    0.0306100   
     downstream 10x|    0.0305972    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1554 at Sat Jan 20 11:07:04 EST 2001
    Right Arm D1 momentum                    : 2.547
    Right Arm arm angle                      : 36.6756
    Left Arm D1 momentum                      : 2.547
    Left Arm arm angle                        : 36.656
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : 2.13938
    Left Arm arm mispointing (HPT)            : 4.99469
    Right Arm Q1 power supply current        : 1915.17
    Right Arm Q1 momentum                    : 2.54698
    Right Arm Q1 gauss meter                 : -0.04762
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1096.17
    Right Arm Q2 momentum                    : 2.54706
    Right Arm Q2 gauss meter                 : 0.5757
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 898.039
    Right Arm D1 momentum                    : 2.547
    Right Arm D1 NMR                         : 0.945161
    Right Arm Q3 power supply current        : 1013.45
    Right Arm Q3 momentum                    : 2.54694
    Right Arm Q3 gauss meter                 : 0.4545
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1916.29
    Left Arm Q1 momentum                      : 2.54713
    Left Arm Q1 gauss meter                   : 0.16269
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1096.65
    Left Arm Q2 momentum                      : 2.54679
    Left Arm Q2 gauss meter                   : -0.5776
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.977
    Left Arm D1 momentum                      : 2.547
    Left Arm D1 NMR                           : 0.942747
    Left Arm Q3 power supply current          : 1014.06
    Left Arm Q3 momentum                      : 2.54713
    Left Arm Q3 gauss meter                   : 0.506
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 38.8324
    Current on Unser monitor                : 48.7516
    Current on Upstream bcm                 : 38.8389
    Current on Downstream bcm               : 38.3927
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 82.8198
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.53
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00977632
    IPM1H04A.XPOS                           : -0.103831
    IPM1H04A.YPOS                           : 0.0637693
    IPM1H04B.XPOS                           : 0.10541
    IPM1H04B.YPOS                           : -0.0997147
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4422
     HacR_VPM_LVDT:VALr                     : 422
     HacR_HPE1313A:0_Ch58                   : -0.530273
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.869141
     HacR_alignROLL                         : -0.388881
     HacR_alignPITCH                        : -0.0246078
     HacR_alignHPT                          : 2.13935
     HacL_HPM_LVDT:VALr                     : -7859
     HacL_VPM_LVDT:VALr                     : 430
     HacL_HPE1313A:0_Ch58                   : -0.168457
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.218262
     HacL_alignROLL                         : 0.139941
     HacL_alignPITCH                        : -0.0939509
     HacL_alignHPT                          : 4.99158
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 39
    haL3_Fan_frequency_R                     : 44.5
    haH2_P_Fill_Target_R                     : 23.76
    haH2_P_Exhaust_R                         : 24.18
    haH2_P_Fill_Bottle_R                     : 24.01
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 42.1
    haD2_DP_Fill_Exhaust_R                   : 0.0785
    haSC200_6_Sensor_1_R                     : 241.58
    haSC200_6_Sensor_2_R                     : 15.01
    haSC200_6_Sensor_3_R                     : 2.74
    haSC200_6_Sensor_4_R                     : 39.75
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 88.42
    haITC502_2_Sensor_1_R                    : 19.01
    haITC502_2_Sensor_2_R                    : 19.01
    haITC502_2_Sensor_3_R                    : 19.08
    haITC502_4_Sensor_1_R                    : 92.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 268.7
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 96.27
    haITC502_6_Sensor_3_R                    : 27.99
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 280
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF