    User name adev

    Log entry time 16:02:57 on January 20, 2001

    Entry number 55299

    keyword=End_of_Run_1572
    ****************************
     Run Number: 1572
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=Kin17,mode=singles,Lmom=2.547,Rmom=-2.547,Ene=5.617,Angle_R=36.676,Angle_L=36.656
    
    
    Time of run = 15.971257 min
    Av. current (on 3x) = 32.294892 uA
    Av. current (on 1x) = 32.219131 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   30.8748  |   30.9474  |   31.0185
    up-down    (mC)|    0.7600  |    0.6876  |    0.8526
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 520.45999 Hz  |     16115.9 /mC  |  520.460 Hz  |    498744  |     1   |     16153.8 /mC
        2      | 52102.183 Hz  |   1613325.8 /mC  |    8.684 Hz  |  49928240  |  6000   |   1617119.5 /mC
        3      | 823.72459 Hz  |     25506.3 /mC  |  823.725 Hz  |    789355  |     1   |     25566.3 /mC
        4      | 84982.195 Hz  |   2631443.9 /mC  |    8.498 Hz  |  81436346  | 10000   |   2637631.5 /mC
        5      | 10.232967 Hz  |       316.9 /mC  |   10.233 Hz  |      9806  |     1   |       317.6 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.060526 Hz  |         1.9 /mC  |    0.061 Hz  | 58.000133  |     1   |         1.9 /mC
        8    | 1024.0 Hz  |     31707.8 /mC  |    0.016 Hz  |    981274  | 65535   |     31782.4 /mC
        output                      1050.383 Hz
    Av. deadtime from accepted triggers = 0.2226
    Av. deadtime from gated scalers = 0.2271
    Accepted triggers  = 1006556.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172441
    Rate of Right Arm Pulser for electronic DT  = 10.170354
    Rate of Left Arm Pulser&trig for electronic DT  = 10.172441
    Rate of Right Arm Pulser&trig for electronic DT  = 10.170354
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 145467.21
    Rate of Right Arm Strobe  = 79385.549
        Signal     |    Charge   (C)   
       upstream    |    0.0312548     
       upstream 3x |    0.0312912     
       upstream 10x|    0.0314448     
      downstream   |    0.0304948   
     downstream 3x |    0.0306036   
     downstream 10x|    0.0305922    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1572 at Sat Jan 20 16:02:45 EST 2001
    Right Arm D1 momentum                    : 2.547
    Right Arm arm angle                      : 36.6756
    Left Arm D1 momentum                      : 2.547
    Left Arm arm angle                        : 36.6561
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : 2.13211
    Left Arm arm mispointing (HPT)            : 4.9811
    Right Arm Q1 power supply current        : 1915.17
    Right Arm Q1 momentum                    : 2.54698
    Right Arm Q1 gauss meter                 : -0.04762
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1096.33
    Right Arm Q2 momentum                    : 2.54742
    Right Arm Q2 gauss meter                 : 0.5757
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 898.041
    Right Arm D1 momentum                    : 2.547
    Right Arm D1 NMR                         : 0.945161
    Right Arm Q3 power supply current        : 1013.65
    Right Arm Q3 momentum                    : 2.54745
    Right Arm Q3 gauss meter                 : 0.4545
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1916.29
    Left Arm Q1 momentum                      : 2.54713
    Left Arm Q1 gauss meter                   : 0.16269
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1096.7
    Left Arm Q2 momentum                      : 2.54692
    Left Arm Q2 gauss meter                   : -0.5776
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.974
    Left Arm D1 momentum                      : 2.547
    Left Arm D1 NMR                           : 0.942748
    Left Arm Q3 power supply current          : 1013.94
    Left Arm Q3 momentum                      : 2.54683
    Left Arm Q3 gauss meter                   : 0.506
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 38.6125
    Current on Unser monitor                : 49.2575
    Current on Upstream bcm                 : 38.5165
    Current on Downstream bcm               : 38.5026
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 86.0625
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.54
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.005247
    IPM1H04A.XPOS                           : -0.147181
    IPM1H04A.YPOS                           : 0.0856341
    IPM1H04B.XPOS                           : 0.0445417
    IPM1H04B.YPOS                           : -0.0760456
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -4415
     HacR_VPM_LVDT:VALr                     : 425
     HacR_HPE1313A:0_Ch58                   : -0.53125
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.870605
     HacR_alignROLL                         : -0.390853
     HacR_alignPITCH                        : -0.0237101
     HacR_alignHPT                          : 2.13152
     HacL_HPM_LVDT:VALr                     : -7850
     HacL_VPM_LVDT:VALr                     : 440
     HacL_HPE1313A:0_Ch58                   : -0.168457
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.217285
     HacL_alignROLL                         : 0.140824
     HacL_alignPITCH                        : -0.0939509
     HacL_alignHPT                          : 4.98333
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 37
    haL3_Fan_frequency_R                     : 44.5
    haH2_P_Fill_Target_R                     : 23.69
    haH2_P_Exhaust_R                         : 24.19
    haH2_P_Fill_Bottle_R                     : 24.01
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.49
    haD2_P_Exhaust_R                         : 21.6
    haD2_P_Fill_Bottle_R                     : 42.42
    haD2_DP_Fill_Exhaust_R                   : 0.0785
    haSC200_6_Sensor_1_R                     : 241.58
    haSC200_6_Sensor_2_R                     : 15.14
    haSC200_6_Sensor_3_R                     : 2.73
    haSC200_6_Sensor_4_R                     : 39.78
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 89.38
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 92.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 268.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 97.01
    haITC502_6_Sensor_3_R                    : 28
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 288
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF