    User name adev

    Log entry time 17:15:03 on January 20, 2001

    Entry number 55308

    keyword=End_of_Run_1571
    ****************************
     Run Number: 1571
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=Kin17,mode=singles,Lmom=2.547,Rmom=-2.547,Ene=5.617,Angle_R=36.676,Angle_L=36.656
    
    Time of run = 13.690902 min
    Av. current (on 3x) = 37.936264 uA
    Av. current (on 1x) = 37.849467 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   31.0916  |   31.1629  |   31.2322
    up-down    (mC)|    0.7598  |    0.6963  |    0.8588
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 613.37207 Hz  |     16168.5 /mC  |  613.372 Hz  |    503857  |     1   |     16205.6 /mC
        2      | 60795.061 Hz  |   1602557.9 /mC  |   10.133 Hz  |  49940352  |  6000   |   1606232.9 /mC
        3      | 971.83519 Hz  |     25617.6 /mC  |  971.835 Hz  |    798318  |     1   |     25676.3 /mC
        4      | 98950.727 Hz  |   2608341.3 /mC  |    9.895 Hz  |  81283480  | 10000   |   2614322.8 /mC
        5      | 10.234291 Hz  |       269.8 /mC  |   10.234 Hz  |      8407  |     1   |       270.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.063303 Hz  |         1.7 /mC  |    0.063 Hz  | 52.000206  |     1   |         1.7 /mC
        8    | 1024.0 Hz  |     26992.6 /mC  |    0.016 Hz  |    841169  | 65535   |     27054.5 /mC
        output                      1225.910 Hz
    Av. deadtime from accepted triggers = 0.2314
    Av. deadtime from gated scalers = 0.2362
    Accepted triggers  = 1007029.00000
    Rate of Left Arm Pulser for electronic DT  = 10.170988
    Rate of Right Arm Pulser for electronic DT  = 10.158815
    Rate of Left Arm Pulser&trig for electronic DT  = 10.170988
    Rate of Right Arm Pulser&trig for electronic DT  = 10.158815
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 169708.18
    Rate of Right Arm Strobe  = 92746.196
        Signal     |    Charge   (C)   
       upstream    |    0.0314715     
       upstream 3x |    0.0315111     
       upstream 10x|    0.0316616     
      downstream   |    0.0307117   
     downstream 3x |    0.0308148   
     downstream 10x|    0.0308028    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1571 at Sat Jan 20 15:46:15 EST 2001
    Right Arm D1 momentum                    : 2.547
    Right Arm arm angle                      : 36.6756
    Left Arm D1 momentum                      : 2.547
    Left Arm arm angle                        : 36.6561
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : 2.13239
    Left Arm arm mispointing (HPT)            : 4.98201
    Right Arm Q1 power supply current        : 1915.06
    Right Arm Q1 momentum                    : 2.54684
    Right Arm Q1 gauss meter                 : -0.04762
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1095.92
    Right Arm Q2 momentum                    : 2.54647
    Right Arm Q2 gauss meter                 : 0.5757
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 898.041
    Right Arm D1 momentum                    : 2.547
    Right Arm D1 NMR                         : 0.945161
    Right Arm Q3 power supply current        : 1013.71
    Right Arm Q3 momentum                    : 2.54759
    Right Arm Q3 gauss meter                 : 0.4545
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1916.35
    Left Arm Q1 momentum                      : 2.54722
    Left Arm Q1 gauss meter                   : 0.1627
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1096.91
    Left Arm Q2 momentum                      : 2.54741
    Left Arm Q2 gauss meter                   : -0.5776
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.976
    Left Arm D1 momentum                      : 2.547
    Left Arm D1 NMR                           : 0.942748
    Left Arm Q3 power supply current          : 1014.09
    Left Arm Q3 momentum                      : 2.54721
    Left Arm Q3 gauss meter                   : 0.506
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 38.3016
    Current on Unser monitor                : 49.6544
    Current on Upstream bcm                 : 38.3832
    Current on Downstream bcm               : 38.1325
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 84.3653
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.26
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.131533
    IPM1H04A.XPOS                           : -0.113786
    IPM1H04A.YPOS                           : 0.0783939
    IPM1H04B.XPOS                           : 0.0842706
    IPM1H04B.YPOS                           : -0.0819941
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -4415
     HacR_VPM_LVDT:VALr                     : 425
     HacR_HPE1313A:0_Ch58                   : -0.531738
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.871094
     HacR_alignROLL                         : -0.390853
     HacR_alignPITCH                        : -0.0232612
     HacR_alignHPT                          : 2.13264
     HacL_HPM_LVDT:VALr                     : -7851
     HacL_VPM_LVDT:VALr                     : 440
     HacL_HPE1313A:0_Ch58                   : -0.167969
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.217773
     HacL_alignROLL                         : 0.140526
     HacL_alignPITCH                        : -0.0945347
     HacL_alignHPT                          : 4.98348
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 37.5
    haL3_Fan_frequency_R                     : 44
    haH2_P_Fill_Target_R                     : 23.71
    haH2_P_Exhaust_R                         : 24.17
    haH2_P_Fill_Bottle_R                     : 23.96
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.47
    haD2_P_Exhaust_R                         : 21.17
    haD2_P_Fill_Bottle_R                     : 41.86
    haD2_DP_Fill_Exhaust_R                   : 0.0782
    haSC200_6_Sensor_1_R                     : 241.59
    haSC200_6_Sensor_2_R                     : 15.13
    haSC200_6_Sensor_3_R                     : 2.71
    haSC200_6_Sensor_4_R                     : 39.76
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 89.17
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 92.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 268.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 97.01
    haITC502_6_Sensor_3_R                    : 28
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617139
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 308
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF