User name adev
Log entry time 23:51:17 on January 21, 2001
Entry number 55390
keyword=Start_Run_1609_RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=,mode=coincidence,Lmom=-3.863,Rmom=2.442,Ene=5.617,Angle_R=36.469,Angle_L=22.052
Beginning-of-run EPICS data for Run Number 1609 at Sun Jan 21 23:51:03 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=12,ps2=5800,ps3=18,ps4=11000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1836.2
Right Arm Q1 momentum : 2.44188
Right Arm Q1 gauss meter : 0.04585
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1050.95
Right Arm Q2 momentum : 2.44197
Right Arm Q2 gauss meter : -0.5526
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 860.036
Right Arm D1 momentum : 2.442
Right Arm D1 NMR : 0.906197
Right Arm Q3 power supply current : 971.772
Right Arm Q3 momentum : 2.4422
Right Arm Q3 gauss meter : -0.4357
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2906.44
Left Arm Q1 momentum : 3.86324
Left Arm Q1 gauss meter : -0.24569
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1663.38
Left Arm Q2 momentum : 3.86293
Left Arm Q2 gauss meter : 0.8756
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1426.99
Left Arm D1 momentum : 3.86299
Left Arm D1 NMR : 1.43107
Left Arm Q3 power supply current : 1538
Left Arm Q3 momentum : 3.86318
Left Arm Q3 gauss meter : -0.7668
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 36.2851
Current on Unser monitor : 46.2518
Current on Upstream bcm : 36.2855
Current on Downstream bcm : 36.2847
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 79.9252
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 4.75458
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26
haL3_Fan_frequency_R : 47
haSC200_6_Sensor_1_R : 241.74
haSC200_6_Sensor_2_R : 14.68
haSC200_6_Sensor_3_R : 2.73
haSC200_6_Sensor_4_R : 39.66
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 86.73
haITC502_4_Sensor_1_R : 90.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22.1
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 97.21
haITC502_5_Sensor_3_R : 268.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 94.3
haITC502_6_Sensor_3_R : 27.94
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4448
HacR_VPM_LVDT:VALr : 332
HacR_HPE1313A:0_Ch58 : -0.530762
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.866211
HacR_alignROLL : -0.385981
HacR_alignPITCH : -0.0240923
HacR_alignHPT : 2.1668
HacL_HPM_LVDT:VALr : -7131
HacL_VPM_LVDT:VALr : 2044
HacL_HPE1313A:0_Ch58 : -0.119629
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.119141
HacL_alignROLL : 0.228053
HacL_alignPITCH : -0.137684
HacL_alignHPT : 4.12539
Right Arm Angle Floor Angle : 36
Right Arm Angle Vernier : 49.8
Right Arm Scattering Angle : 36.4694
Left Arm Angle Floor Angle : 22
Left Arm Angle Vernier : 44.8
Left Arm Scattering Angle : 22.0513
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 282
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88