    User name adev

    Log entry time 11:33:41 on January 22, 2001

    Entry number 55425

    keyword=End_of_Run_1622
    ****************************
     Run Number: 1622
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=1-empty,comment=kin16,mode=coincidence,Lmom=-3.863,Rmom=2.442,Ene=5.617,Angle_R=36.469,Angle_L=22.052
    
    Time of run = 47.231397 min
    Av. current (on 3x) = 40.938164 uA
    Av. current (on 1x) = 40.858627 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  115.7886  |  116.0140  |  116.1142
    up-down    (mC)|    2.8250  |    2.5663  |    2.9874
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 575.5303 Hz  |     14058.5 /mC  |   57.553 Hz  |   1630986  |    10   |     14085.9 /mC
        2      | 25756.224 Hz  |    629149.5 /mC  |    4.293 Hz  |  72990146  |  6000   |    630374.2 /mC
        3      | 1220.9453 Hz  |     29824.1 /mC  |   61.047 Hz  |   3460017  |    20   |     29882.2 /mC
        4      | 51093.898 Hz  |   1248075.0 /mC  |    5.109 Hz  | 144794170  | 10000   |   1250504.5 /mC
        5      | 70.133786 Hz  |      1713.2 /mC  |   70.134 Hz  |    198751  |     1   |      1716.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 59.961174 Hz  |      1464.7 /mC  |   59.961 Hz  | 169923.0  |     1   |      1467.5 /mC
        8    | 1024.0 Hz  |     25013.3 /mC  |    0.016 Hz  |   2901897  | 65535   |     25062.0 /mC
        output                       181.562 Hz
    Av. deadtime from accepted triggers = 0.0324
    Av. deadtime from gated scalers = 0.0544
    Accepted triggers  = 514526.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172612
    Rate of Right Arm Pulser for electronic DT  = 10.16873
    Rate of Left Arm Pulser&trig for electronic DT  = 10.172612
    Rate of Right Arm Pulser&trig for electronic DT  = 10.16873
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 81217.036
    Rate of Right Arm Strobe  = 38770.185
        Signal     |    Charge   (C)   
       upstream    |    0.1172011     
       upstream 3x |    0.1172972     
       upstream 10x|    0.1176079     
      downstream   |    0.1143761   
     downstream 3x |    0.1147309   
     downstream 10x|    0.1146205    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1622 at Mon Jan 22 11:33:30 EST 2001
    Right Arm D1 momentum                    : 2.442
    Right Arm arm angle                      : 36.4693
    Left Arm D1 momentum                      : 3.863
    Left Arm arm angle                        : 22.0511
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : 2.1696
    Left Arm arm mispointing (HPT)            : 4.15673
    Right Arm Q1 power supply current        : 1836.14
    Right Arm Q1 momentum                    : 2.44188
    Right Arm Q1 gauss meter                 : 0.04585
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1050.98
    Right Arm Q2 momentum                    : 2.44171
    Right Arm Q2 gauss meter                 : -0.5525
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 860.027
    Right Arm D1 momentum                    : 2.442
    Right Arm D1 NMR                         : 0.906196
    Right Arm Q3 power supply current        : 971.801
    Right Arm Q3 momentum                    : 2.44227
    Right Arm Q3 gauss meter                 : -0.4357
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2906.4
    Left Arm Q1 momentum                      : 3.86319
    Left Arm Q1 gauss meter                   : -0.24571
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1663.16
    Left Arm Q2 momentum                      : 3.86243
    Left Arm Q2 gauss meter                   : 0.8756
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1426.98
    Left Arm D1 momentum                      : 3.863
    Left Arm D1 NMR                           : 1.43107
    Left Arm Q3 power supply current          : 1537.8
    Left Arm Q3 momentum                      : 3.86266
    Left Arm Q3 gauss meter                   : -0.7667
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 39.1158
    Current on Unser monitor                : 50.6024
    Current on Upstream bcm                 : 39.2479
    Current on Downstream bcm               : 38.8972
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 85.2882
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.63
    Delta(E)/E width (MV_AI_DXWID)          : 1.34551
    IPM1C12.XPOS                            : 0.000728399
    IPM1H04A.XPOS                           : -0.136703
    IPM1H04A.YPOS                           : 0.110155
    IPM1H04B.XPOS                           : 0.056176
    IPM1H04B.YPOS                           : -0.0310674
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617139
     HacR_HPM_LVDT:VALr                     : -4450
     HacR_VPM_LVDT:VALr                     : 300
     HacR_HPE1313A:0_Ch58                   : -0.529785
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.867188
     HacR_alignROLL                         : -0.386966
     HacR_alignPITCH                        : -0.0254389
     HacR_alignHPT                          : 2.1696
     HacL_HPM_LVDT:VALr                     : Inf
     HacL_VPM_LVDT:VALr                     : 2005
     HacL_HPE1313A:0_Ch58                   : -0.118164
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.124512
     HacL_alignROLL                         : 0.223783
     HacL_alignPITCH                        : -0.139143
     HacL_alignHPT                          : 4.15673
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 38
    haL3_Fan_frequency_R                     : 46.5
    haH2_P_Fill_Target_R                     : 24.04
    haH2_P_Exhaust_R                         : 24.54
    haH2_P_Fill_Bottle_R                     : 24.44
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.3
    haD2_P_Exhaust_R                         : 21.01
    haD2_P_Fill_Bottle_R                     : 41.34
    haD2_DP_Fill_Exhaust_R                   : 0.0795
    haSC200_6_Sensor_1_R                     : 241.71
    haSC200_6_Sensor_2_R                     : 14.9
    haSC200_6_Sensor_3_R                     : 2.74
    haSC200_6_Sensor_4_R                     : 39.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 88.47
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.1
    haITC502_4_Sensor_1_R                    : 92.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 98.97
    haITC502_5_Sensor_3_R                    : 268.4
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 97.11
    haITC502_6_Sensor_3_R                    : 27.97
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 264
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF