Main INDEX
Monthly INDEX
PREV
NEXT
User name S. Sirca
Log entry time 23:14:58 on January23,2001
Entry number 55501
keyword=ROC1 crash and consequences
CODA failed to end run #1644 cleanly due to the ROC1 crash. It could not
be reset from the counting house using usual procedures. Accessed hall
at approx. 20:45 to reset ROC1 on the Right HRS. By mistake also pressed
reset on the HV crate controllers which caused some commotion
later on. CODA restarted well. There is some condensed water dripping
from Q2 on Left HRS, forming a puddle on the support frame. Resumed
full data taking at 22:54.