User name adev
Log entry time 07:18:57 on January 24, 2001
Entry number 55531
keyword=Start_Run_1663_RunType=Other,Tar=LH2-15cm,Rad=6,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Beginning-of-run EPICS data for Run Number 1663 at Wed Jan 24 07:18:47 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=5,ps2=4700,ps3=4,ps4=7600,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : 0.05604
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1286.82
Right Arm Q2 momentum : 2.99003
Right Arm Q2 gauss meter : -0.6761
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 1072.1
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.53
Right Arm Q3 momentum : 2.98947
Right Arm Q3 gauss meter : -0.533
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2249.59
Left Arm Q1 momentum : 2.99016
Left Arm Q1 gauss meter : -0.19033
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1287.32
Left Arm Q2 momentum : 2.98959
Left Arm Q2 gauss meter : 0.6787
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1044.95
Left Arm D1 momentum : 2.99
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.3
Left Arm Q3 momentum : 2.98981
Left Arm Q3 gauss meter : -0.5938
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 46.8643
Current on Unser monitor : 57.5884
Current on Upstream bcm : 46.815
Current on Downstream bcm : 46.9136
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 61.8613
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.03541
Radiator Encoder : 4.7033
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.59
haSC200_6_Sensor_2_R : 15.26
haSC200_6_Sensor_3_R : 2.59
haSC200_6_Sensor_4_R : 39.45
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 95.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.05
haITC502_5_Sensor_2_R : 84.2
haITC502_5_Sensor_3_R : 268.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3047
HacR_VPM_LVDT:VALr : 38
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.769531
HacR_alignROLL : -0.288316
HacR_alignPITCH : -0.0120393
HacR_alignHPT : 0.569407
HacL_HPM_LVDT:VALr : -7869
HacL_VPM_LVDT:VALr : 622
HacL_HPE1313A:0_Ch58 : -0.156738
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.237305
HacL_alignROLL : 0.122928
HacL_alignPITCH : -0.104214
HacL_alignHPT : 5.01539
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : 71.7
Right Arm Scattering Angle : 31.1064
Left Arm Angle Floor Angle : 31
Left Arm Angle Vernier : 50.1
Left Arm Scattering Angle : 31.0758
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 306
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88