User name adev
Log entry time 07:23:05 on January 24, 2001
Entry number 55535
keyword=Start_Run_1665_RunType=Other,Tar=LH2-15cm,Rad=6,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Beginning-of-run EPICS data for Run Number 1665 at Wed Jan 24 07:22:52 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1800,ps3=1,ps4=3000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : 0.05605
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1286.85
Right Arm Q2 momentum : 2.99011
Right Arm Q2 gauss meter : -0.6761
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 1072.1
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1190.01
Right Arm Q3 momentum : 2.99066
Right Arm Q3 gauss meter : -0.5331
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2249.66
Left Arm Q1 momentum : 2.99025
Left Arm Q1 gauss meter : -0.19033
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1287.51
Left Arm Q2 momentum : 2.99004
Left Arm Q2 gauss meter : 0.6787
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1044.95
Left Arm D1 momentum : 2.99
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.45
Left Arm Q3 momentum : 2.99019
Left Arm Q3 gauss meter : -0.5938
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 47.2725
Current on Unser monitor : 58.8564
Current on Upstream bcm : 47.1838
Current on Downstream bcm : 47.3611
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 61.5593
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.25519
Radiator Encoder : 0.525031
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 73
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.63
haSC200_6_Sensor_2_R : 15.26
haSC200_6_Sensor_3_R : 2.63
haSC200_6_Sensor_4_R : 39.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 95.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.1
haITC502_5_Sensor_2_R : 84.23
haITC502_5_Sensor_3_R : 268.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3048
HacR_VPM_LVDT:VALr : 38
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.769043
HacR_alignROLL : -0.289302
HacR_alignPITCH : -0.0120393
HacR_alignHPT : 0.569969
HacL_HPM_LVDT:VALr : -7868
HacL_VPM_LVDT:VALr : 622
HacL_HPE1313A:0_Ch58 : -0.156738
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.237305
HacL_alignROLL : 0.122558
HacL_alignPITCH : -0.104724
HacL_alignHPT : 5.01445
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : 71.7
Right Arm Scattering Angle : 31.1064
Left Arm Angle Floor Angle : 31
Left Arm Angle Vernier : 50.1
Left Arm Scattering Angle : 31.0758
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 306
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88