User name adev
Log entry time 09:26:47 on January 24, 2001
Entry number 55547
keyword=Start_Run_1668_RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Beginning-of-run EPICS data for Run Number 1668 at Wed Jan 24 09:26:36 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1800,ps3=1,ps4=3000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : 0.05606
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1287
Right Arm Q2 momentum : 2.99047
Right Arm Q2 gauss meter : -0.676
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 1072.08
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1190
Right Arm Q3 momentum : 2.99063
Right Arm Q3 gauss meter : -0.5331
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2249.59
Left Arm Q1 momentum : 2.99016
Left Arm Q1 gauss meter : -0.19033
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1287.51
Left Arm Q2 momentum : 2.99003
Left Arm Q2 gauss meter : 0.6788
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1044.95
Left Arm D1 momentum : 2.99
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.23
Left Arm Q3 momentum : 2.98965
Left Arm Q3 gauss meter : -0.5938
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 46.6813
Current on Unser monitor : 58.5975
Current on Upstream bcm : 46.6483
Current on Downstream bcm : 46.7143
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 117.014
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.522589
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 37.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.59
haSC200_6_Sensor_2_R : 15.19
haSC200_6_Sensor_3_R : 2.64
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 95.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22.2
haITC502_5_Sensor_1_R : 85.33
haITC502_5_Sensor_2_R : 83.37
haITC502_5_Sensor_3_R : 269.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.06
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3059
HacR_VPM_LVDT:VALr : 48
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.767578
HacR_alignROLL : -0.285911
HacR_alignPITCH : -0.0124218
HacR_alignHPT : 0.580349
HacL_HPM_LVDT:VALr : -7868
HacL_VPM_LVDT:VALr : 646
HacL_HPE1313A:0_Ch58 : -0.157227
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.233398
HacL_alignROLL : 0.126021
HacL_alignPITCH : -0.105087
HacL_alignHPT : 5.00832
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : 71.7
Right Arm Scattering Angle : 31.1063
Left Arm Angle Floor Angle : 31
Left Arm Angle Vernier : 50.1
Left Arm Scattering Angle : 31.0758
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 315
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88