    User name adev

    Log entry time 11:40:50 on January 24, 2001

    Entry number 55557

    keyword=End_of_Run_1671
    ****************************
     Run Number: 1671
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
    
    Time of run = 31.388655 min
    Av. current (on 3x) = 36.269315 uA
    Av. current (on 1x) = 36.198854 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   68.1740  |   68.3067  |   68.4343
    up-down    (mC)|    1.7081  |    1.5430  |    1.8823
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 369.11425 Hz  |     10177.0 /mC  |  369.114 Hz  |    695160  |     1   |     10196.8 /mC
        2      | 24337.504 Hz  |    671021.9 /mC  |   13.521 Hz  |  45835291  |  1800   |    672328.0 /mC
        3      | 220.54518 Hz  |      6080.8 /mC  |  220.545 Hz  |    415357  |     1   |      6092.6 /mC
        4      | 37970.576 Hz  |   1046906.4 /mC  |   12.657 Hz  |  71510719  |  3000   |   1048944.2 /mC
        5      | 10.72946 Hz  |       295.8 /mC  |   10.729 Hz  |     20207  |     1   |       296.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.555402 Hz  |        15.3 /mC  |    0.555 Hz  | 1046.0002  |     1   |        15.3 /mC
        8    | 1024.0 Hz  |     28233.2 /mC  |    0.016 Hz  |   1928519  | 65535   |     28288.2 /mC
        output                       532.750 Hz
    Av. deadtime from accepted triggers = 0.1196
    Av. deadtime from gated scalers = 0.1289
    Accepted triggers  = 1003339.00000
    Rate of Left Arm Pulser for electronic DT  = 10.174058
    Rate of Right Arm Pulser for electronic DT  = 10.173527
    Rate of Left Arm Pulser&trig for electronic DT  = 10.174058
    Rate of Right Arm Pulser&trig for electronic DT  = 10.173527
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 60345.342
    Rate of Right Arm Strobe  = 35830.338
        Signal     |    Charge   (C)   
       upstream    |    0.0690281     
       upstream 3x |    0.0690782     
       upstream 10x|    0.0693754     
      downstream   |    0.0673200   
     downstream 3x |    0.0675352   
     downstream 10x|    0.0674931    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1671 at Wed Jan 24 11:40:34 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1064
    Left Arm D1 momentum                      : 2.99
    Left Arm arm angle                        : 31.0759
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : 0.571709
    Left Arm arm mispointing (HPT)            : 5.00101
    Right Arm Q1 power supply current        : 2248.23
    Right Arm Q1 momentum                    : 2.98992
    Right Arm Q1 gauss meter                 : 0.05605
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1286.75
    Right Arm Q2 momentum                    : 2.9899
    Right Arm Q2 gauss meter                 : -0.676
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 1072.08
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.79
    Right Arm Q3 momentum                    : 2.9901
    Right Arm Q3 gauss meter                 : -0.533
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2249.7
    Left Arm Q1 momentum                      : 2.9903
    Left Arm Q1 gauss meter                   : -0.19035
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1287.54
    Left Arm Q2 momentum                      : 2.99011
    Left Arm Q2 gauss meter                   : 0.6788
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1044.96
    Left Arm D1 momentum                      : 2.99
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.33
    Left Arm Q3 momentum                      : 2.98988
    Left Arm Q3 gauss meter                   : -0.5938
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 
    Current on Unser monitor                : 
    Current on Upstream bcm                 : 
    Current on Downstream bcm               : 
    Upstream Cavity Coefficient             : 
    Downstream Cavity Coefficient           : 
     Current on IBC0L02 (source)            : 89.2974
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.91
    Tiefenbach Hall C energy                : 3395.37
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.0060229
    IPM1H04A.XPOS                           : -0.215066
    IPM1H04A.YPOS                           : 0.190661
    IPM1H04B.XPOS                           : 0.0107779
    IPM1H04B.YPOS                           : 0.0549583
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -3051
     HacR_VPM_LVDT:VALr                     : 42
     HacR_HPE1313A:0_Ch58                   : -0.54248
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.767578
     HacR_alignROLL                         : -0.286404
     HacR_alignPITCH                        : -0.0133196
     HacR_alignHPT                          : 0.571675
     HacL_HPM_LVDT:VALr                     : -7860
     HacL_VPM_LVDT:VALr                     : 656
     HacL_HPE1313A:0_Ch58                   : -0.15625
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.232422
     HacL_alignROLL                         : 0.127346
     HacL_alignPITCH                        : -0.105087
     HacL_alignHPT                          : 5.00098
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 39.5
    haL3_Fan_frequency_R                     : 44.1468
    haH2_P_Fill_Target_R                     : 23.88
    haH2_P_Exhaust_R                         : 24.35
    haH2_P_Fill_Bottle_R                     : 24.35
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.72
    haD2_P_Exhaust_R                         : 18.81
    haD2_P_Fill_Bottle_R                     : 37.26
    haD2_DP_Fill_Exhaust_R                   : 0.0787
    haSC200_6_Sensor_1_R                     : 241.44
    haSC200_6_Sensor_2_R                     : 15.03
    haSC200_6_Sensor_3_R                     : 2.59
    haSC200_6_Sensor_4_R                     : 39.45
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.08
    haITC502_4_Sensor_1_R                    : 95.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 85.07
    haITC502_5_Sensor_2_R                    : 83.12
    haITC502_5_Sensor_3_R                    : 269.3
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.05
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 325
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON