• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 13:55:03 on January 24, 2001

    Entry number 55567

    keyword=End_of_Run_1676
    ****************************
     Run Number: 1676
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
    
    Time of run = 28.69873 min
    Av. current (on 3x) = 25.390729 uA
    Av. current (on 1x) = 25.339681 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   43.6330  |   43.7209  |   43.8252
    up-down    (mC)|    1.1191  |    0.9732  |    1.2156
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 728.54269 Hz  |     28693.3 /mC  |  364.271 Hz  |   1254495  |     2   |     28751.1 /mC
        2      | 45295.432 Hz  |   1783935.9 /mC  |   12.582 Hz  |  77995283  |  3600   |   1787529.7 /mC
        3      | 507.45625 Hz  |     19985.9 /mC  |  253.728 Hz  |    873801  |     2   |     20026.2 /mC
        4      | 70891.427 Hz  |   2792020.3 /mC  |   11.815 Hz  | 122069640  |  6000   |   2797644.9 /mC
        5      | 11.209555 Hz  |       441.5 /mC  |   11.210 Hz  |     19302  |     1   |       442.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.035469 Hz  |        40.8 /mC  |    1.035 Hz  | 1782.9992  |     1   |        40.9 /mC
        8    | 1024.0 Hz  |     40329.7 /mC  |    0.016 Hz  |   1763250  | 65535   |     40410.9 /mC
        output                       582.429 Hz
    Av. deadtime from accepted triggers = 0.0934
    Av. deadtime from gated scalers = 0.1594
    Accepted triggers  = 1002898.00000
    Rate of Left Arm Pulser for electronic DT  = 10.174086
    Rate of Right Arm Pulser for electronic DT  = 10.168278
    Rate of Left Arm Pulser&trig for electronic DT  = 10.172924
    Rate of Right Arm Pulser&trig for electronic DT  = 10.168278
    Left Arm Electronic DT  = 0.00011416177
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 113193.58
    Rate of Right Arm Strobe  = 67755.628
        Signal     |    Charge   (C)   
       upstream    |    0.0441926     
       upstream 3x |    0.0442075     
       upstream 10x|    0.0444330     
      downstream   |    0.0430735   
     downstream 3x |    0.0432343   
     downstream 10x|    0.0432174    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1676 at Wed Jan 24 13:54:52 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1064
    Left Arm D1 momentum                      : 2.99
    Left Arm arm angle                        : 31.0759
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : 0.573424
    Left Arm arm mispointing (HPT)            : 4.99541
    Right Arm Q1 power supply current        : 2248.26
    Right Arm Q1 momentum                    : 2.98997
    Right Arm Q1 gauss meter                 : 0.05605
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1286.99
    Right Arm Q2 momentum                    : 2.99044
    Right Arm Q2 gauss meter                 : -0.676
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 1072.08
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.62
    Right Arm Q3 momentum                    : 2.98967
    Right Arm Q3 gauss meter                 : -0.533
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2249.66
    Left Arm Q1 momentum                      : 2.99025
    Left Arm Q1 gauss meter                   : -0.19033
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1287.45
    Left Arm Q2 momentum                      : 2.9899
    Left Arm Q2 gauss meter                   : 0.6788
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1044.96
    Left Arm D1 momentum                      : 2.99
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.29
    Left Arm Q3 momentum                      : 2.98979
    Left Arm Q3 gauss meter                   : -0.5938
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 37.2165
    Current on Unser monitor                : 47.5762
    Current on Upstream bcm                 : 37.1723
    Current on Downstream bcm               : 37.2608
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 79.3796
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.92
    Tiefenbach Hall C energy                : 3395.4
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00371966
    IPM1H04A.XPOS                           : -0.229813
    IPM1H04A.YPOS                           : 0.208277
    IPM1H04B.XPOS                           : -0.0149502
    IPM1H04B.YPOS                           : 0.075431
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -3052
     HacR_VPM_LVDT:VALr                     : 43
     HacR_HPE1313A:0_Ch58                   : -0.542969
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.766113
     HacR_alignROLL                         : -0.286956
     HacR_alignPITCH                        : -0.0119067
     HacR_alignHPT                          : 0.573109
     HacL_HPM_LVDT:VALr                     : -7856
     HacL_VPM_LVDT:VALr                     : 670
     HacL_HPE1313A:0_Ch58                   : -0.15625
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.230957
     HacL_alignROLL                         : 0.128229
     HacL_alignPITCH                        : -0.105087
     HacL_alignHPT                          : 4.99497
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 37.5
    haL3_Fan_frequency_R                     : 44.5
    haH2_P_Fill_Target_R                     : 24.18
    haH2_P_Exhaust_R                         : 24.66
    haH2_P_Fill_Bottle_R                     : 24.59
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.7
    haD2_P_Exhaust_R                         : 18.3
    haD2_P_Fill_Bottle_R                     : 36.2
    haD2_DP_Fill_Exhaust_R                   : 0.0796
    haSC200_6_Sensor_1_R                     : 241.44
    haSC200_6_Sensor_2_R                     : 14.9
    haSC200_6_Sensor_3_R                     : 2.56
    haSC200_6_Sensor_4_R                     : 39.43
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.08
    haITC502_4_Sensor_1_R                    : 94.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 85.96
    haITC502_5_Sensor_2_R                    : 84.01
    haITC502_5_Sensor_3_R                    : 269.3
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.05
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 291
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON