User name adev
Log entry time 14:17:24 on January 24, 2001
Entry number 55569
keyword=End_of_Run_1677
****************************
Run Number: 1677
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=kin16,mode=singles,Lmom=-2.99,Rmom=2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Time of run = 21.672315 min
Av. current (on 3x) = 28.548019 uA
Av. current (on 1x) = 28.490573 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 37.0474 | 37.1221 | 37.2082
up-down (mC)| 0.9375 | 0.8263 | 1.0279
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 817.33308 Hz | 28630.1 /mC | 408.667 Hz | 1062810 | 2 | 28687.8 /mC
2 | 50555.997 Hz | 1770910.8 /mC | 14.043 Hz | 65739929 | 3600 | 1774481.6 /mC
3 | 571.27876 Hz | 20011.2 /mC | 285.639 Hz | 742856 | 2 | 20051.5 /mC
4 | 79301.486 Hz | 2777828.0 /mC | 13.217 Hz | 103118810 | 6000 | 2783429.1 /mC
5 | 11.287058 Hz | 395.4 /mC | 11.287 Hz | 14677 | 1 | 396.2 /mC
Trigger 5 corrected for pulser:
5 (phys) | 1.11048 Hz | 38.9 /mC | 1.110 Hz | 1443.9998 | 1 | 39.0 /mC
8 | 1024.0 Hz | 35869.4 /mC | 0.016 Hz | 1331547 | 65535 | 35941.7 /mC
output 576.747 Hz
Av. deadtime from accepted triggers = 0.2007
Av. deadtime from gated scalers = 0.2584
Accepted triggers = 749967.00000
Rate of Left Arm Pulser for electronic DT = 10.176578
Rate of Right Arm Pulser for electronic DT = 10.168888
Rate of Left Arm Pulser&trig for electronic DT = 10.175809
Rate of Right Arm Pulser&trig for electronic DT = 10.168888
Left Arm Electronic DT = 7.5568654e-05
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 126734.59
Rate of Right Arm Strobe = 75757.059
Signal | Charge (C)
upstream | 0.0375162
upstream 3x | 0.0375352
upstream 10x| 0.0377222
downstream | 0.0365787
downstream 3x | 0.0367089
downstream 10x| 0.0366943
****************************
End-of-run EPICS data for Run Number 1677 at Wed Jan 24 14:17:14 EST 2001
Right Arm D1 momentum : 2.99
Right Arm arm angle : 31.1064
Left Arm D1 momentum : 2.99
Left Arm arm angle : 31.0811
Tiefenbach Hall A energy : 5614.91
Right Arm arm mispointing (HPT) : 0.573352
Left Arm arm mispointing (HPT) : 4.99472
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : 0.05606
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1286.96
Right Arm Q2 momentum : 2.99037
Right Arm Q2 gauss meter : -0.6761
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 1072.09
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.96
Right Arm Q3 momentum : 2.99053
Right Arm Q3 gauss meter : -0.5331
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2249.55
Left Arm Q1 momentum : 2.99011
Left Arm Q1 gauss meter : -0.19034
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1287.41
Left Arm Q2 momentum : 2.9898
Left Arm Q2 gauss meter : 0.6787
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1044.96
Left Arm D1 momentum : 2.99
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.27
Left Arm Q3 momentum : 2.98974
Left Arm Q3 gauss meter : -0.5938
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 37.4495
Current on Unser monitor : 47.9461
Current on Upstream bcm : 37.4525
Current on Downstream bcm : 37.4466
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 37.7767
MBSY1c Hall A Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
MBSY1c Bdl : 1.40413e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5614.92
Tiefenbach Hall C energy : 3394.89
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00240415
IPM1H04A.XPOS : -0.23685
IPM1H04A.YPOS : 0.161043
IPM1H04B.XPOS : -0.016884
IPM1H04B.YPOS : 0.0100643
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -3053
HacR_VPM_LVDT:VALr : 43
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.766602
HacR_alignROLL : -0.285418
HacR_alignPITCH : -0.011973
HacR_alignHPT : 0.573352
HacL_HPM_LVDT:VALr : -7856
HacL_VPM_LVDT:VALr : 672
HacL_HPE1313A:0_Ch58 : -0.15625
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.230957
HacL_alignROLL : 0.128671
HacL_alignPITCH : -0.105013
HacL_alignHPT : 4.99591
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 37.5
haL3_Fan_frequency_R : 44.5
haH2_P_Fill_Target_R : 24.38
haH2_P_Exhaust_R : 24.82
haH2_P_Fill_Bottle_R : 24.77
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 29.7
haD2_P_Exhaust_R : 18.76
haD2_P_Fill_Bottle_R : 37.13
haD2_DP_Fill_Exhaust_R : 0.0783
haSC200_6_Sensor_1_R : 241.48
haSC200_6_Sensor_2_R : 14.85
haSC200_6_Sensor_3_R : 2.61
haSC200_6_Sensor_4_R : 39.45
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.08
haITC502_4_Sensor_1_R : 94.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22.1
haITC502_5_Sensor_1_R : 86.13
haITC502_5_Sensor_2_R : 84.18
haITC502_5_Sensor_3_R : 269.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 285
Laser power Hall A : 57
Half-wave plate (off=out) : ON