User name adev
Log entry time 07:19:06 on January 25, 2001
Entry number 55662
keyword=Start_Run_1711_RunType=pion_prod,Tar=dum-15cm,Rad=out,comment=kin16,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Beginning-of-run EPICS data for Run Number 1711 at Thu Jan 25 07:18:46 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=300000,ps3=1,ps4=300000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.26
Right Arm Q1 momentum : 2.98997
Right Arm Q1 gauss meter : -0.05584
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1286.63
Right Arm Q2 momentum : 2.98981
Right Arm Q2 gauss meter : 0.6754
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.97
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.86
Right Arm Q3 momentum : 2.99027
Right Arm Q3 gauss meter : 0.5335
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2249.66
Left Arm Q1 momentum : 2.99025
Left Arm Q1 gauss meter : 0.19079
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1287.39
Left Arm Q2 momentum : 2.98975
Left Arm Q2 gauss meter : -0.6779
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1045.78
Left Arm D1 momentum : 2.99001
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.38
Left Arm Q3 momentum : 2.99
Left Arm Q3 gauss meter : 0.5941
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.0965
Current on Unser monitor : 38.6186
Current on Upstream bcm : 28.0627
Current on Downstream bcm : 28.1303
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 68.2031
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 0.14652
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 51
haL3_Fan_frequency_R : 36.5
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 14.85
haSC200_6_Sensor_3_R : 2.68
haSC200_6_Sensor_4_R : 39.6
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 94.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 87.86
haITC502_5_Sensor_2_R : 85.71
haITC502_5_Sensor_3_R : 270.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.11
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3036
HacR_VPM_LVDT:VALr : 33
HacR_HPE1313A:0_Ch58 : -0.542969
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.76416
HacR_alignROLL : -0.282894
HacR_alignPITCH : -0.0124882
HacR_alignHPT : 0.552884
HacL_HPM_LVDT:VALr : -8032
HacL_VPM_LVDT:VALr : 737
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.258301
HacL_alignROLL : 0.103863
HacL_alignPITCH : -0.111999
HacL_alignHPT : 5.19397
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : 71.7
Right Arm Scattering Angle : 31.1065
Left Arm Angle Floor Angle : 28
Left Arm Angle Vernier : -36
Left Arm Scattering Angle : 27.5783
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 297
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88