User name adev
Log entry time 08:53:27 on January 25, 2001
Entry number 55670
keyword=Start_Run_1714_RunType=Other,Tar=BeO,Rad=out,comment=beam_spot_check,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
Beginning-of-run EPICS data for Run Number 1714 at Thu Jan 25 08:53:17 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=5000,ps3=1,ps4=5200,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.23
Right Arm Q1 momentum : 2.98992
Right Arm Q1 gauss meter : -0.05585
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1286.79
Right Arm Q2 momentum : 2.98999
Right Arm Q2 gauss meter : 0.6754
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.96
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.72
Right Arm Q3 momentum : 2.98994
Right Arm Q3 gauss meter : 0.5334
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2249.55
Left Arm Q1 momentum : 2.99011
Left Arm Q1 gauss meter : 0.19077
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1287.67
Left Arm Q2 momentum : 2.99041
Left Arm Q2 gauss meter : -0.678
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1045.78
Left Arm D1 momentum : 2.99001
Left Arm D1 NMR : 1.10713
Left Arm Q3 power supply current : 1190.27
Left Arm Q3 momentum : 2.98973
Left Arm Q3 gauss meter : 0.5941
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.379712
Current on Unser monitor : 11.344
Current on Upstream bcm : 0.380417
Current on Downstream bcm : 0.379008
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 43.4584
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.153846
haBDSPOS : 190450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 49
haL3_Fan_frequency_R : 44.5
haSC200_6_Sensor_1_R : 241.59
haSC200_6_Sensor_2_R : 14.85
haSC200_6_Sensor_3_R : 2.63
haSC200_6_Sensor_4_R : 39.58
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 94.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 87.83
haITC502_5_Sensor_2_R : 85.65
haITC502_5_Sensor_3_R : 272.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.25
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3040
HacR_VPM_LVDT:VALr : 44
HacR_HPE1313A:0_Ch58 : -0.542969
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.764648
HacR_alignROLL : -0.280548
HacR_alignPITCH : -0.0128044
HacR_alignHPT : 0.556024
HacL_HPM_LVDT:VALr : -8032
HacL_VPM_LVDT:VALr : 753
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.258301
HacL_alignROLL : 0.104304
HacL_alignPITCH : -0.111562
HacL_alignHPT : 5.19152
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : 71.7
Right Arm Scattering Angle : 31.1065
Left Arm Angle Floor Angle : 28
Left Arm Angle Vernier : -36
Left Arm Scattering Angle : 27.5783
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 150
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88