    User name adev

    Log entry time 09:25:47 on January 25, 2001

    Entry number 55675

    keyword=Start_Run_1715_RunType=Cosmic,Tar=BeO,Rad=out,comment=beam_spot_check,mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.11,Angle_L=31.11
    Beginning-of-run EPICS data for Run Number 1715 at Thu Jan 25 09:25:35 EST 2001
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=1,ps2=5000,ps3=1,ps4=5200,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 2261.1
    Right Arm Q1 momentum                    : 3.00705
    Right Arm Q1 gauss meter                 : -0.05615
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1294.01
    Right Arm Q2 momentum                    : 3.00675
    Right Arm Q2 gauss meter                 : 0.6793
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1093.12
    Right Arm D1 momentum                    : 3.00381
    Right Arm D1 NMR                         : 1.11468
    Right Arm Q3 power supply current        : 1196.4
    Right Arm Q3 momentum                    : 3.00671
    Right Arm Q3 gauss meter                 : 0.5365
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1309.67
    Left Arm Q1 momentum                      : 1.74081
    Left Arm Q1 gauss meter                   : 0.11149
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 749.681
    Left Arm Q2 momentum                      : 1.74101
    Left Arm Q2 gauss meter                   : 0
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 657.457
    Left Arm D1 momentum                      : 1.97142
    Left Arm D1 NMR                           : 0.7295
    Left Arm Q3 power supply current          : 885.449
    Left Arm Q3 momentum                      : 2.22408
    Left Arm Q3 gauss meter                   : 0.4482
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0419813
    Current on Unser monitor                : 10.9815
    Current on Upstream bcm                 : 0.0511037
    Current on Downstream bcm               : 0.0328588
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.00142881
    Beam energy                             : 5626.62
    MBSY1c magnet current (amp)             : 0.0377197
     Radiator 5V Linear Supply              : 5.00122
     Radiator Encoder                       : 0.166056
    haBDSPOS                                 : 190450
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 52.5
    haL3_Fan_frequency_R                     : 41.5
    haSC200_6_Sensor_1_R                     : 241.59
    haSC200_6_Sensor_2_R                     : 14.85
    haSC200_6_Sensor_3_R                     : 2.61
    haSC200_6_Sensor_4_R                     : 39.56
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 94.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.85
    haITC502_5_Sensor_2_R                    : 85.62
    haITC502_5_Sensor_3_R                    : 272.7
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.28
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -3044
     HacR_VPM_LVDT:VALr                     : 52
     HacR_HPE1313A:0_Ch58                   : -0.542969
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.763184
     HacR_alignROLL                         : -0.282401
     HacR_alignPITCH                        : -0.0124882
     HacR_alignHPT                          : 0.560439
     HacL_HPM_LVDT:VALr                     : -8042
     HacL_VPM_LVDT:VALr                     : 754
     HacL_HPE1313A:0_Ch58                   : -0.149902
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.256836
     HacL_alignROLL                         : 0.104746
     HacL_alignPITCH                        : -0.110689
     HacL_alignHPT                          : 5.20248
    Right Arm Angle Floor Angle               : 30.5
    Right Arm Angle Vernier                   : 71.7
    Right Arm Scattering Angle                : 31.1065
    Left Arm Angle Floor Angle                 : 28
    Left Arm Angle Vernier                     : -36
    Left Arm Scattering Angle                  : 27.5783
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 250
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88