Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 05:57:09 on January 26, 2001
Entry number 55762
keyword=Start_Run_1747_RunType=Optics,Tar=9foil-12C,Rad=out,comment=run_with_10_mA,mode=coincidence,Lmom=1.741,Rmom=-3.077,Ene=5.617,Angle_R=21.151,Angle_L=22.371
Beginning-of-run EPICS data for Run Number 1747 at Fri Jan 26 05:56:56 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=7500,ps3=10,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2241.5
Right Arm Q1 momentum : 2.98098
Right Arm Q1 gauss meter : -0.05569
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1282.91
Right Arm Q2 momentum : 2.98096
Right Arm Q2 gauss meter : 0.6735
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 0
Right Arm D1 momentum : 2.98102
Right Arm D1 NMR : 1.10622
Right Arm Q3 power supply current : 1186.13
Right Arm Q3 momentum : 2.98091
Right Arm Q3 gauss meter : 0.5319
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.7
Left Arm Q1 momentum : 1.74085
Left Arm Q1 gauss meter : 0.11151
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.552
Left Arm Q2 momentum : 1.74071
Left Arm Q2 gauss meter : -0.3953
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 585.665
Left Arm D1 momentum : 1.74101
Left Arm D1 NMR : 0.644291
Left Arm Q3 power supply current : 693.073
Left Arm Q3 momentum : 1.74087
Left Arm Q3 gauss meter : 0.3462
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 10.5578
Current on Unser monitor : 20.6981
Current on Upstream bcm : 10.5479
Current on Downstream bcm : 10.5676
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 82.983
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.156288
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.46
haSC200_6_Sensor_2_R : 14.78
haSC200_6_Sensor_3_R : 2.58
haSC200_6_Sensor_4_R : 39.55
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.72
haITC502_5_Sensor_2_R : 83.62
haITC502_5_Sensor_3_R : 270
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1754
HacR_VPM_LVDT:VALr : -187
HacR_HPE1313A:0_Ch58 : -0.530762
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.777344
HacR_alignROLL : -0.297683
HacR_alignPITCH : -0.0246078
HacR_alignHPT : -0.846085
HacL_HPM_LVDT:VALr : -7203
HacL_VPM_LVDT:VALr : 1861
HacL_HPE1313A:0_Ch58 : -0.122559
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.146484
HacL_alignROLL : 0.204945
HacL_alignPITCH : -0.135064
HacL_alignHPT : 4.21693
Right Arm Angle Floor Angle : 21
Right Arm Angle Vernier : 49
Right Arm Scattering Angle : 21.4852
Left Arm Angle Floor Angle : 23
Left Arm Angle Vernier : -73
Left Arm Scattering Angle : 22.3717
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 126
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88