Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 09:42:23 on January 27, 2001
Entry number 55841
keyword=End_of_Run_1766
****************************
Run Number: 1766
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics_3,mode=coincidence,Lmom=2.266,Rmom=-2.719,Ene=5.617,Angle_R=22.509,Angle_L=18.806
Time of run = 79.310253 min
Av. current (on 3x) = 68.157497 uA
Av. current (on 1x) = 67.995012 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 323.5621 | 324.3353 | -39.0451
up-down (mC)| -0.7824 | 0.7658 | -12.6989
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 6793.5836 Hz | 99674.8 /mC | 9.058 Hz | 32328050 | 750 | 99913.0 /mC
2 | 49280.487 Hz | 723038.4 /mC | 6.571 Hz | 234506870 | 7500 | 724766.2 /mC
3 | 135429.28 Hz | 1987005.0 /mC | 5.643 Hz | 644455850 | 24000 | 1991753.2 /mC
4 | 65525.887 Hz | 961389.3 /mC | 8.737 Hz | 311812480 | 7500 | 963686.7 /mC
5 | 74.433209 Hz | 1092.1 /mC | 74.433 Hz | 354199 | 1 | 1094.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 64.259661 Hz | 942.8 /mC | 64.260 Hz | 305787.0 | 1 | 945.1 /mC
8 | 1024.0 Hz | 15024.0 /mC | 0.016 Hz | 4872822 | 65535 | 15059.9 /mC
output 104.454 Hz
Av. deadtime from accepted triggers = -0.0009
Av. deadtime from gated scalers = -0.5115
Accepted triggers = 497055.00000
Rate of Left Arm Pulser for electronic DT = 10.173548
Rate of Right Arm Pulser for electronic DT = 10.171447
Rate of Left Arm Pulser&trig for electronic DT = 10.093483
Rate of Right Arm Pulser&trig for electronic DT = 10.171447
Left Arm Electronic DT = 0.0078699496
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 302637.18
Rate of Right Arm Strobe = 51724.286
Signal | Charge (C)
upstream | 0.3231709
upstream 3x | 0.3247182
upstream 10x| -0.0453946
downstream | 0.3239533
downstream 3x | 0.3239524
downstream 10x| -0.0326957
****************************
End-of-run EPICS data for Run Number 1766 at Sat Jan 27 09:42:12 EST 2001
Right Arm D1 momentum : 2.719
Right Arm arm angle : 22.5088
Left Arm D1 momentum : 2.26599
Left Arm arm angle : 18.8063
Tiefenbach Hall A energy : 5614.9
Right Arm arm mispointing (HPT) : 0.774193
Left Arm arm mispointing (HPT) : 3.8668
Right Arm Q1 power supply current : 2044.49
Right Arm Q1 momentum : 2.71897
Right Arm Q1 gauss meter : -0.05083
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1170.05
Right Arm Q2 momentum : 2.71873
Right Arm Q2 gauss meter : 0.6144
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 964.369
Right Arm D1 momentum : 2.719
Right Arm D1 NMR : 1.00899
Right Arm Q3 power supply current : 1081.93
Right Arm Q3 momentum : 2.71888
Right Arm Q3 gauss meter : 0.4851
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1704.85
Left Arm Q1 momentum : 2.26609
Left Arm Q1 gauss meter : 0.14473
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 975.955
Left Arm Q2 momentum : 2.2665
Left Arm Q2 gauss meter : -0.5142
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 775.06
Left Arm D1 momentum : 2.26599
Left Arm D1 NMR : 0.838477
Left Arm Q3 power supply current : 902.16
Left Arm Q3 momentum : 2.26606
Left Arm Q3 gauss meter : 0.4503
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 77.2603
Current on Unser monitor : 87.5575
Current on Upstream bcm : 77.2679
Current on Downstream bcm : 77.2526
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 121.775
MBSY1c Hall A Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
MBSY1c Bdl : 1.40413e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5614.9
Tiefenbach Hall C energy : 3395.64
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00452304
IPM1H04A.XPOS : -0.0590307
IPM1H04A.YPOS : 0.0547194
IPM1H04B.XPOS : -0.0553267
IPM1H04B.YPOS : -0.0457729
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -3207
HacR_VPM_LVDT:VALr : -225
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.771484
HacR_alignROLL : -0.290347
HacR_alignPITCH : -0.0240923
HacR_alignHPT : 0.772826
HacL_HPM_LVDT:VALr : -6912
HacL_VPM_LVDT:VALr : 1952
HacL_HPE1313A:0_Ch58 : -0.138184
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0849609
HacL_alignROLL : 0.260825
HacL_alignPITCH : -0.141793
HacL_alignHPT : 3.86495
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 20
haH2_P_Fill_Target_R : 23.59
haH2_P_Exhaust_R : 23.9
haH2_P_Fill_Bottle_R : 23.98
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 29.65
haD2_P_Exhaust_R : 18.7
haD2_P_Fill_Bottle_R : 36.98
haD2_DP_Fill_Exhaust_R : 0.0767
haSC200_6_Sensor_1_R : 241.9
haSC200_6_Sensor_2_R : 15.23
haSC200_6_Sensor_3_R : 2.82
haSC200_6_Sensor_4_R : 39.7
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.27
haITC502_4_Sensor_1_R : 94.5
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 84.99
haITC502_5_Sensor_2_R : 82.98
haITC502_5_Sensor_3_R : 267
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.97
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 600
Laser power Hall A : 57
Half-wave plate (off=out) : OFF