• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 13:45:20 on January 27, 2001

    Entry number 55861

    keyword=Start_Run_1772_RunType=Optics,Tar=LH2-15cm,Rad=out,comment=kinematics_4,mode=coincidence,Lmom=2.542,Rmom=-2.504,Ene=5.617,Angle_R=23.451,Angle_L=16.95
    Beginning-of-run EPICS data for Run Number 1772 at Sat Jan 27 13:45:06 EST 2001
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=750,ps2=7500,ps3=24000,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
    ;ps1=1,ps2=7500,ps3=10,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 1882.86
    Right Arm Q1 momentum                    : 2.50402
    Right Arm Q1 gauss meter                 : -0.04684
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1077.76
    Right Arm Q2 momentum                    : 2.50428
    Right Arm Q2 gauss meter                 : 0.566
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 881.456
    Right Arm D1 momentum                    : 2.504
    Right Arm D1 NMR                         : 0.929204
    Right Arm Q3 power supply current        : 996.217
    Right Arm Q3 momentum                    : 2.50363
    Right Arm Q3 gauss meter                 : 0.4468
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1912.51
    Left Arm Q1 momentum                      : 2.5421
    Left Arm Q1 gauss meter                   : 0.16226
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1094.43
    Left Arm Q2 momentum                      : 2.54165
    Left Arm Q2 gauss meter                   : -0.5766
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.207
    Left Arm D1 momentum                      : 2.542
    Left Arm D1 NMR                           : 0.940892
    Left Arm Q3 power supply current          : 1012.12
    Left Arm Q3 momentum                      : 2.54225
    Left Arm Q3 gauss meter                   : 0.5053
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 83.2726
    Current on Unser monitor                : 94.3161
    Current on Upstream bcm                 : 83.8694
    Current on Downstream bcm               : 83.6005
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 129
    Beam energy                             : 5626.62
    MBSY1c magnet current (amp)             : 235.16
     Radiator 5V Linear Supply              : 5.0696
     Radiator Encoder                       : 0.156288
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69.5
    haL3_Fan_frequency_R                     : 19.5
    haSC200_6_Sensor_1_R                     : 241.41
    haSC200_6_Sensor_2_R                     : 14.98
    haSC200_6_Sensor_3_R                     : 2.56
    haSC200_6_Sensor_4_R                     : 39.48
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 94.4
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.31
    haITC502_5_Sensor_2_R                    : 83.24
    haITC502_5_Sensor_3_R                    : 266.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.95
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -3627
     HacR_VPM_LVDT:VALr                     : -309
     HacR_HPE1313A:0_Ch58                   : -0.539062
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.734863
     HacR_alignROLL                         : -0.253808
     HacR_alignPITCH                        : -0.0156303
     HacR_alignHPT                          : 1.22326
     HacL_HPM_LVDT:VALr                     : -7249
     HacL_VPM_LVDT:VALr                     : 2048
     HacL_HPE1313A:0_Ch58                   : -0.13916
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.00976562
     HacL_alignROLL                         : 0.331558
     HacL_alignPITCH                        : -0.141132
     HacL_alignHPT                          : 4.20867
    Right Arm Angle Floor Angle               : 23
    Right Arm Angle Vernier                   : 45.6
    Right Arm Scattering Angle                : 23.4515
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 27.4
    Left Arm Scattering Angle                  : 16.9504
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 443
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88