User name adev
Log entry time 14:58:16 on January 28, 2001
Entry number 55966
keyword=Start_Run_1815_RunType=Optics,Tar=9foil-12C,Rad=out,comment=kin4,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
Beginning-of-run EPICS data for Run Number 1815 at Sun Jan 28 14:58:02 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=7500,ps3=10,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2285.11
Right Arm Q1 momentum : 3.03898
Right Arm Q1 gauss meter : -0.05676
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1307.87
Right Arm Q2 momentum : 3.03897
Right Arm Q2 gauss meter : 0.6866
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1092.62
Right Arm D1 momentum : 3.039
Right Arm D1 NMR : 1.12774
Right Arm Q3 power supply current : 1209.24
Right Arm Q3 momentum : 3.03899
Right Arm Q3 gauss meter : 0.5423
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.11
Left Arm Q1 momentum : 1.98598
Left Arm Q1 gauss meter : 0.12706
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.084
Left Arm Q2 momentum : 1.9858
Left Arm Q2 gauss meter : -0.4508
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 672.778
Left Arm D1 momentum : 1.98601
Left Arm D1 NMR : 0.734895
Left Arm Q3 power supply current : 790.583
Left Arm Q3 momentum : 1.9858
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 24.5761
Current on Unser monitor : 35.6517
Current on Upstream bcm : 24.6324
Current on Downstream bcm : 24.5198
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 61.7155
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.151404
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67
haL3_Fan_frequency_R : 19.5
haSC200_6_Sensor_1_R : 241.51
haSC200_6_Sensor_2_R : 14.81
haSC200_6_Sensor_3_R : 2.61
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.33
haITC502_5_Sensor_2_R : 83.18
haITC502_5_Sensor_3_R : 270
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1019
HacR_VPM_LVDT:VALr : -174
HacR_HPE1313A:0_Ch58 : -0.511719
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.777832
HacR_alignROLL : -0.297249
HacR_alignPITCH : -0.0420469
HacR_alignHPT : -1.67131
HacL_HPM_LVDT:VALr : -7547
HacL_VPM_LVDT:VALr : 2043
HacL_HPE1313A:0_Ch58 : -0.119629
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.168457
HacL_alignROLL : 0.183366
HacL_alignPITCH : -0.138482
HacL_alignHPT : 4.61054
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -15
Right Arm Scattering Angle : 19.1219
Left Arm Angle Floor Angle : 20.5
Left Arm Angle Vernier : -5.4
Left Arm Scattering Angle : 20.2586
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 245
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88