    User name adev

    Log entry time 16:02:22 on January 28, 2001

    Entry number 55980

    keyword=End_of_Run_1820
    ****************************
     Run Number: 1820
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin5 first production,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
    
    
    Time of run = 27.450407 min
    Av. current (on 3x) = 66.152936 uA
    Av. current (on 1x) = 65.996351 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  108.6976  |  108.9555  |   99.0789
    up-down    (mC)|   -0.1860  |    0.3272  |   -2.3089
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 14336.697 Hz  |    216720.5 /mC  |   19.116 Hz  |  23612889  |   750   |    217234.7 /mC
        2      | 52924.295 Hz  |    800029.4 /mC  |    7.057 Hz  |  87167606  |  7500   |    801927.6 /mC
        3      | 170610.03 Hz  |   2579024.3 /mC  |    7.109 Hz  | 280998880  | 24000   |   2585143.4 /mC
        4      | 62292.435 Hz  |    941642.8 /mC  |    8.306 Hz  | 102597160  |  7500   |    943877.0 /mC
        5      | 274.27645 Hz  |      4146.1 /mC  |  274.276 Hz  |    451740  |     1   |      4155.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 264.09992 Hz  |      3992.3 /mC  |  264.100 Hz  | 434979.0  |     1   |      4001.7 /mC
        8    | 1024.0 Hz  |     15479.3 /mC  |    0.016 Hz  |   1686553  | 65535   |     15516.0 /mC
        output                       303.873 Hz
    Av. deadtime from accepted triggers = 0.0369
    Av. deadtime from gated scalers = 0.0888
    Accepted triggers  = 500486.00000
    Rate of Left Arm Pulser for electronic DT  = 10.176534
    Rate of Right Arm Pulser for electronic DT  = 10.176534
    Rate of Left Arm Pulser&trig for electronic DT  = 10.067853
    Rate of Right Arm Pulser&trig for electronic DT  = 10.176534
    Left Arm Electronic DT  = 0.010679554
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 347388.52
    Rate of Right Arm Strobe  = 62905.467
        Signal     |    Charge   (C)   
       upstream    |    0.1086046     
       upstream 3x |    0.1091191     
       upstream 10x|    0.0979244     
      downstream   |    0.1087906   
     downstream 3x |    0.1087919   
     downstream 10x|    0.1002333    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1820 at Sun Jan 28 16:02:13 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.122
    Left Arm D1 momentum                      : 1.98601
    Left Arm arm angle                        : 20.2586
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : -1.68338
    Left Arm arm mispointing (HPT)            : 4.61325
    Right Arm Q1 power supply current        : 2285.19
    Right Arm Q1 momentum                    : 3.03907
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.91
    Right Arm Q2 momentum                    : 3.03905
    Right Arm Q2 gauss meter                 : 0.6865
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.62
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.48
    Right Arm Q3 momentum                    : 3.0396
    Right Arm Q3 gauss meter                 : 0.5423
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.19
    Left Arm Q1 momentum                      : 1.98607
    Left Arm Q1 gauss meter                   : 0.12705
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 854.972
    Left Arm Q2 momentum                      : 1.98554
    Left Arm Q2 gauss meter                   : -0.4509
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 672.782
    Left Arm D1 momentum                      : 1.98601
    Left Arm D1 NMR                           : 0.734896
    Left Arm Q3 power supply current          : 790.711
    Left Arm Q3 momentum                      : 1.98612
    Left Arm Q3 gauss meter                   : 0.3949
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 82.9516
    Current on Unser monitor                : 94.1797
    Current on Upstream bcm                 : 83.0106
    Current on Downstream bcm               : 83.1327
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 115.733
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.91
    Tiefenbach Hall C energy                : 3395.64
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00618154
    IPM1H04A.XPOS                           : -0.0368065
    IPM1H04A.YPOS                           : 0.157953
    IPM1H04B.XPOS                           : -0.0170986
    IPM1H04B.YPOS                           : 0.0659165
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617139
     HacR_HPM_LVDT:VALr                     : -1008
     HacR_VPM_LVDT:VALr                     : -174
     HacR_HPE1313A:0_Ch58                   : -0.511719
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.776367
     HacR_alignROLL                         : -0.294725
     HacR_alignPITCH                        : -0.0407673
     HacR_alignHPT                          : -1.68394
     HacL_HPM_LVDT:VALr                     : -7549
     HacL_VPM_LVDT:VALr                     : 2048
     HacL_HPE1313A:0_Ch58                   : -0.118652
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.167969
     HacL_alignROLL                         : 0.184691
     HacL_alignPITCH                        : -0.138045
     HacL_alignHPT                          : 4.61549
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 67
    haL3_Fan_frequency_R                     : 20
    haH2_P_Fill_Target_R                     : 23.59
    haH2_P_Exhaust_R                         : 24.03
    haH2_P_Fill_Bottle_R                     : 24.02
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.01
    haD2_P_Exhaust_R                         : 19
    haD2_P_Fill_Bottle_R                     : 37.47
    haD2_DP_Fill_Exhaust_R                   : 0.077
    haSC200_6_Sensor_1_R                     : 241.34
    haSC200_6_Sensor_2_R                     : 14.83
    haSC200_6_Sensor_3_R                     : 2.61
    haSC200_6_Sensor_4_R                     : 39.46
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.27
    haITC502_4_Sensor_1_R                    : 93.6
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.4
    haITC502_5_Sensor_2_R                    : 83.21
    haITC502_5_Sensor_3_R                    : 266.6
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.93
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617139
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 535
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF