User name adev
Log entry time 16:27:05 on January 28, 2001
Entry number 55985
keyword=End_of_Run_1821
****************************
Run Number: 1821
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin5 first production,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
Time of run = 22.64891 min
Av. current (on 3x) = 78.789369 uA
Av. current (on 1x) = 78.604371 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 106.8182 | 107.0696 | 96.5045
up-down (mC)| -0.2013 | 0.3265 | -2.4495
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 17024.462 Hz | 216075.6 /mC | 22.699 Hz | 23135130 | 750 | 216584.2 /mC
2 | 62992.37 Hz | 799503.4 /mC | 8.399 Hz | 85602511 | 7500 | 801385.1 /mC
3 | 202185.94 Hz | 2566157.6 /mC | 8.424 Hz | 274757470 | 24000 | 2572197.2 /mC
4 | 74061.709 Hz | 939996.2 /mC | 9.875 Hz | 100645020 | 7500 | 942208.5 /mC
5 | 334.22285 Hz | 4242.0 /mC | 334.223 Hz | 454187 | 1 | 4252.0 /mC
Trigger 5 corrected for pulser:
5 (phys) | 324.0465 Hz | 4112.8 /mC | 324.046 Hz | 440358.0 | 1 | 4122.5 /mC
8 | 1024.0 Hz | 12996.7 /mC | 0.016 Hz | 1391549 | 65535 | 13027.3 /mC
output 368.505 Hz
Av. deadtime from accepted triggers = 0.0383
Av. deadtime from gated scalers = 0.0935
Accepted triggers = 500774.00000
Rate of Left Arm Pulser for electronic DT = 10.176354
Rate of Right Arm Pulser for electronic DT = 10.16826
Rate of Left Arm Pulser&trig for electronic DT = 10.046105
Rate of Right Arm Pulser&trig for electronic DT = 10.167524
Left Arm Electronic DT = 0.01279919
Right Arm Electronic DT = 7.2369373e-05
Rate of Left Strobe = 416421.15
Rate of Right Arm Strobe = 75106.85
Signal | Charge (C)
upstream | 0.1067175
upstream 3x | 0.1072329
upstream 10x| 0.0952798
downstream | 0.1069188
downstream 3x | 0.1069064
downstream 10x| 0.0977293
****************************
End-of-run EPICS data for Run Number 1821 at Sun Jan 28 16:26:52 EST 2001
Right Arm D1 momentum : 3.039
Right Arm arm angle : 19.122
Left Arm D1 momentum : 1.98601
Left Arm arm angle : 20.2586
Tiefenbach Hall A energy : 5614.9
Right Arm arm mispointing (HPT) : -1.68419
Left Arm arm mispointing (HPT) : 4.61347
Right Arm Q1 power supply current : 2285.19
Right Arm Q1 momentum : 3.03907
Right Arm Q1 gauss meter : -0.05675
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1307.77
Right Arm Q2 momentum : 3.03896
Right Arm Q2 gauss meter : 0.6866
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1092.61
Right Arm D1 momentum : 3.039
Right Arm D1 NMR : 1.12774
Right Arm Q3 power supply current : 1209.21
Right Arm Q3 momentum : 3.03891
Right Arm Q3 gauss meter : 0.5423
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.11
Left Arm Q1 momentum : 1.98598
Left Arm Q1 gauss meter : 0.12703
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.134
Left Arm Q2 momentum : 1.98591
Left Arm Q2 gauss meter : -0.4509
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 672.782
Left Arm D1 momentum : 1.98601
Left Arm D1 NMR : 0.734895
Left Arm Q3 power supply current : 790.557
Left Arm Q3 momentum : 1.98604
Left Arm Q3 gauss meter : 0.395
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 83.7226
Current on Unser monitor : 94.7953
Current on Upstream bcm : 83.8669
Current on Downstream bcm : 83.5783
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 118.274
MBSY1c Hall A Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
MBSY1c Bdl : 1.40413e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5614.9
Tiefenbach Hall C energy : 3395.61
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00277796
IPM1H04A.XPOS : -0.044709
IPM1H04A.YPOS : 0.158831
IPM1H04B.XPOS : -0.0131235
IPM1H04B.YPOS : 0.0616729
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1007
HacR_VPM_LVDT:VALr : -176
HacR_HPE1313A:0_Ch58 : -0.512207
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.776855
HacR_alignROLL : -0.296697
HacR_alignPITCH : -0.0407673
HacR_alignHPT : -1.68618
HacL_HPM_LVDT:VALr : -7549
HacL_VPM_LVDT:VALr : 2047
HacL_HPE1313A:0_Ch58 : -0.119629
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.166992
HacL_alignROLL : 0.183662
HacL_alignPITCH : -0.138333
HacL_alignHPT : 4.61487
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 71.5
haL3_Fan_frequency_R : 19.5
haH2_P_Fill_Target_R : 23.56
haH2_P_Exhaust_R : 23.95
haH2_P_Fill_Bottle_R : 23.93
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 29.98
haD2_P_Exhaust_R : 18.92
haD2_P_Fill_Bottle_R : 37.34
haD2_DP_Fill_Exhaust_R : 0.077
haSC200_6_Sensor_1_R : 241.38
haSC200_6_Sensor_2_R : 14.8
haSC200_6_Sensor_3_R : 2.64
haSC200_6_Sensor_4_R : 39.48
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19.01
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.28
haITC502_4_Sensor_1_R : 93.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.42
haITC502_5_Sensor_2_R : 83.27
haITC502_5_Sensor_3_R : 266.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.93
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 517
Laser power Hall A : 57
Half-wave plate (off=out) : OFF