    User name adev

    Log entry time 16:27:05 on January 28, 2001

    Entry number 55985

    keyword=End_of_Run_1821
    ****************************
     Run Number: 1821
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin5 first production,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
    
    
    Time of run = 22.64891 min
    Av. current (on 3x) = 78.789369 uA
    Av. current (on 1x) = 78.604371 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  106.8182  |  107.0696  |   96.5045
    up-down    (mC)|   -0.2013  |    0.3265  |   -2.4495
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 17024.462 Hz  |    216075.6 /mC  |   22.699 Hz  |  23135130  |   750   |    216584.2 /mC
        2      | 62992.37 Hz  |    799503.4 /mC  |    8.399 Hz  |  85602511  |  7500   |    801385.1 /mC
        3      | 202185.94 Hz  |   2566157.6 /mC  |    8.424 Hz  | 274757470  | 24000   |   2572197.2 /mC
        4      | 74061.709 Hz  |    939996.2 /mC  |    9.875 Hz  | 100645020  |  7500   |    942208.5 /mC
        5      | 334.22285 Hz  |      4242.0 /mC  |  334.223 Hz  |    454187  |     1   |      4252.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 324.0465 Hz  |      4112.8 /mC  |  324.046 Hz  | 440358.0  |     1   |      4122.5 /mC
        8    | 1024.0 Hz  |     12996.7 /mC  |    0.016 Hz  |   1391549  | 65535   |     13027.3 /mC
        output                       368.505 Hz
    Av. deadtime from accepted triggers = 0.0383
    Av. deadtime from gated scalers = 0.0935
    Accepted triggers  = 500774.00000
    Rate of Left Arm Pulser for electronic DT  = 10.176354
    Rate of Right Arm Pulser for electronic DT  = 10.16826
    Rate of Left Arm Pulser&trig for electronic DT  = 10.046105
    Rate of Right Arm Pulser&trig for electronic DT  = 10.167524
    Left Arm Electronic DT  = 0.01279919
    Right Arm Electronic DT  = 7.2369373e-05
    Rate of Left Strobe  = 416421.15
    Rate of Right Arm Strobe  = 75106.85
        Signal     |    Charge   (C)   
       upstream    |    0.1067175     
       upstream 3x |    0.1072329     
       upstream 10x|    0.0952798     
      downstream   |    0.1069188   
     downstream 3x |    0.1069064   
     downstream 10x|    0.0977293    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1821 at Sun Jan 28 16:26:52 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.122
    Left Arm D1 momentum                      : 1.98601
    Left Arm arm angle                        : 20.2586
    Tiefenbach Hall A energy                : 5614.9
    Right Arm arm mispointing (HPT)          : -1.68419
    Left Arm arm mispointing (HPT)            : 4.61347
    Right Arm Q1 power supply current        : 2285.19
    Right Arm Q1 momentum                    : 3.03907
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.77
    Right Arm Q2 momentum                    : 3.03896
    Right Arm Q2 gauss meter                 : 0.6866
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.61
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.21
    Right Arm Q3 momentum                    : 3.03891
    Right Arm Q3 gauss meter                 : 0.5423
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.11
    Left Arm Q1 momentum                      : 1.98598
    Left Arm Q1 gauss meter                   : 0.12703
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 855.134
    Left Arm Q2 momentum                      : 1.98591
    Left Arm Q2 gauss meter                   : -0.4509
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 672.782
    Left Arm D1 momentum                      : 1.98601
    Left Arm D1 NMR                           : 0.734895
    Left Arm Q3 power supply current          : 790.557
    Left Arm Q3 momentum                      : 1.98604
    Left Arm Q3 gauss meter                   : 0.395
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 83.7226
    Current on Unser monitor                : 94.7953
    Current on Upstream bcm                 : 83.8669
    Current on Downstream bcm               : 83.5783
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 118.274
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.9
    Tiefenbach Hall C energy                : 3395.61
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00277796
    IPM1H04A.XPOS                           : -0.044709
    IPM1H04A.YPOS                           : 0.158831
    IPM1H04B.XPOS                           : -0.0131235
    IPM1H04B.YPOS                           : 0.0616729
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -1007
     HacR_VPM_LVDT:VALr                     : -176
     HacR_HPE1313A:0_Ch58                   : -0.512207
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.776855
     HacR_alignROLL                         : -0.296697
     HacR_alignPITCH                        : -0.0407673
     HacR_alignHPT                          : -1.68618
     HacL_HPM_LVDT:VALr                     : -7549
     HacL_VPM_LVDT:VALr                     : 2047
     HacL_HPE1313A:0_Ch58                   : -0.119629
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.166992
     HacL_alignROLL                         : 0.183662
     HacL_alignPITCH                        : -0.138333
     HacL_alignHPT                          : 4.61487
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 71.5
    haL3_Fan_frequency_R                     : 19.5
    haH2_P_Fill_Target_R                     : 23.56
    haH2_P_Exhaust_R                         : 23.95
    haH2_P_Fill_Bottle_R                     : 23.93
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.98
    haD2_P_Exhaust_R                         : 18.92
    haD2_P_Fill_Bottle_R                     : 37.34
    haD2_DP_Fill_Exhaust_R                   : 0.077
    haSC200_6_Sensor_1_R                     : 241.38
    haSC200_6_Sensor_2_R                     : 14.8
    haSC200_6_Sensor_3_R                     : 2.64
    haSC200_6_Sensor_4_R                     : 39.48
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19.01
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.28
    haITC502_4_Sensor_1_R                    : 93.6
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.42
    haITC502_5_Sensor_2_R                    : 83.27
    haITC502_5_Sensor_3_R                    : 266.5
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.93
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 517
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF